Show simple item record

dc.contributor.authorParker, Matthew D.
dc.contributor.authorTaberner, A. J.
dc.contributor.authorNash, M. P.
dc.contributor.authorNielsen, P. M. F.
dc.contributor.authorJones, Lynette A
dc.contributor.authorHunter, Ian
dc.date.accessioned2017-03-10T15:04:33Z
dc.date.available2017-03-10T15:04:33Z
dc.date.issued2016-11
dc.date.submitted2016-10
dc.identifier.issn0148-0731
dc.identifier.urihttp://hdl.handle.net/1721.1/107307
dc.description.abstractA triaxial force-sensitive microrobot was developed to dynamically perturb skin in multiple deformation modes, in vivo. Wiener static nonlinear identification was used to extract the linear dynamics and static nonlinearity of the force–displacement behavior of skin. Stochastic input forces were applied to the volar forearm and thenar eminence of the hand, producing probe tip perturbations in indentation and tangential extension. Wiener static nonlinear approaches reproduced the resulting displacements with variances accounted for (VAF) ranging 94–97%, indicating a good fit to the data. These approaches provided VAF improvements of 0.1–3.4% over linear models. Thenar eminence stiffness measures were approximately twice those measured on the forearm. Damping was shown to be significantly higher on the palm, whereas the perturbed mass typically was lower. Coefficients of variation (CVs) for nonlinear parameters were assessed within and across individuals. Individual CVs ranged from 2% to 11% for indentation and from 2% to 19% for extension. Stochastic perturbations with incrementally increasing mean amplitudes were applied to the same test areas. Differences between full-scale and incremental reduced-scale perturbations were investigated. Different incremental preloading schemes were investigated. However, no significant difference in parameters was found between different incremental preloading schemes. Incremental schemes provided depth-dependent estimates of stiffness and damping, ranging from 300 N/m and 2 Ns/m, respectively, at the surface to 5 kN/m and 50 Ns/m at greater depths. The device and techniques used in this research have potential applications in areas, such as evaluating skincare products, assessing skin hydration, or analyzing wound healing.en_US
dc.description.sponsorshipFoundation for Research, Science & Technology (N.Z.) (Grants UOA21647.001 and NERF 9077/3608892)en_US
dc.description.sponsorshipTertiary Education Commission of New Zealand (Medical Technologies Centre of Research Excellence (MedTech CoRE))en_US
dc.language.isoen_US
dc.publisherASME Internationalen_US
dc.relation.isversionofhttp://dx.doi.org/10.1115/1.4034993en_US
dc.rightsArticle is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.en_US
dc.sourceAmerican Society of Mechanical Engineers (ASME)en_US
dc.titleMultidirectional In Vivo Characterization of Skin Using Wiener Nonlinear Stochastic System Identification Techniquesen_US
dc.typeArticleen_US
dc.identifier.citationParker, Matthew D. et al. “Multidirectional In Vivo Characterization of Skin Using Wiener Nonlinear Stochastic System Identification Techniques.” Journal of Biomechanical Engineering 139.1 (2016): 011004. © 2017 ASMEen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineeringen_US
dc.contributor.mitauthorJones, Lynette A
dc.contributor.mitauthorHunter, Ian
dc.relation.journalJournal of Biomechanical Engineeringen_US
dc.eprint.versionFinal published versionen_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dspace.orderedauthorsParker, Matthew D.; Jones, Lynette A.; Hunter, Ian W.; Taberner, A. J.; Nash, M. P.; Nielsen, P. M. F.en_US
dspace.embargo.termsNen_US
dc.identifier.orcidhttps://orcid.org/0000-0003-1361-8654
dc.identifier.orcidhttps://orcid.org/0000-0002-8251-5432
mit.licensePUBLISHER_POLICYen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record