MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

An MRI Coil-Mounted Multi-Probe Robotic Positioner for Cryoablation

Author(s)
Torabi, Meysam; Yamada, Atsushi; Golden, Alex; Fischer, Gregory S.; Tuncali, Kemal; Walsh, Conor; Wu, Faye Y; Frey, Daniel; ... Show more Show less
Thumbnail
Downloadv06at07a012-detc2013-13132.pdf (1.908Mb)
PUBLISHER_POLICY

Publisher Policy

Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.

Terms of use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Metadata
Show full item record
Abstract
Cryoablation is a percutaneous procedure for treating solid tumors using needle-like instruments. This paper presents an interventional guidance device for faster and more accurate alignment and insertion of multiple probes during cryoablation performed in closed bore magnetic resonance (MR) imaging systems. The device is compact and is intended to be mounted onto a Siemens 110 mm MR loop coil. A cable-driven two-degrees-of-freedom spherical mechanism mimics the wrist motion as it orients the intervention probes about a remote center of motion located 15 mm above the skin. A carriage interfaces with the probes via a thumbscrew-fastened latch to passively release the probes from their tracks, enabling them to be inserted sequentially and freeing them to move with respiration. Small actuator modules containing piezoelectric encoder-based motors are designed to be snap-fit into the device for ease of replacement and sterilization. The robot MRI compatibility was validated with standard cryoablation imaging sequences in 3T MR environment, yielding a maximum of 4% signal to noise ratio during actuator motion. Bench-level device characterization demonstrated a maximum error of 0.78° in the carriage movement. Needle-tip placement experiments for multiple targets in gelatin were performed using our image-guided navigation software, measuring an average targeting error of 2.0 mm. Copyright © 2013 by ASME.
Date issued
2013-08
URI
http://hdl.handle.net/1721.1/119147
Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Journal
Proceedings of the ASME 2013 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference IDETC/CIE 2013
Publisher
American Society of Mechanical Engineers
Citation
Wu, Faye Y., et al. “An MRI Coil-Mounted Multi-Probe Robotic Positioner for Cryoablation.” Proceedings of the ASME 2013 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference IDETC/CIE 2013, 4-7 August, 2013, Portland, Oregon, ASME, 2013, p. V06AT07A012.
Version: Final published version
ISBN
978-0-7918-5593-5

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.