dc.contributor.authorLi, Liang
dc.contributor.authorWu, Julia
dc.contributor.authorDing, Hui
dc.contributor.authorWang, Guangzhi
dc.date.accessioned2021-09-20T17:17:09Z
dc.date.available2021-09-20T17:17:09Z
dc.date.issued2019-07-17
dc.identifier.urihttps://hdl.handle.net/1721.1/131455
dc.description.abstractAbstract Purpose Current stereotactic surgical robots system relies on cumbersome operations such as calibration, tracking and registration to establish the accurate intraoperative coordinate transformation chain, which makes the system not easy to use. To overcome this problem, a novel stereotactic surgical robot system has been proposed and validated. Methods First, a hand–eye integrated scheme is proposed to avoid the intraoperative calibration between robot arm and motion tracking system. Second, a special reference-tool-based patient registration and tracking method is developed to avoid intraoperative registration. Third, a model-free visual servo method is used to reduce the accuracy requirement of hand–eye relationship and robot kinematic model. Finally, a prototype of the system is constructed and performance tests and a pedicle screw drilling experiment are performed. Results The results show that the proposed system has acceptable accuracy. The target positioning error in the plane was − 0.68 ± 0.52 mm and 0.06 ± 0.41 mm. The orientation error was 0.43 ± 0.25°. The pedicle screw drilling experiment shows that the system can complete accurate stereotactic surgery. Conclusions The stereotactic surgical robot system described in this paper can perform stereotactic surgery without the intraoperative hand–eye calibration and nor manual registration and can achieve an acceptable position and orientation accuracy while tolerating the errors in the hand–eye coordinate transformation error and the robot kinematics model error.en_US
dc.publisherSpringer International Publishingen_US
dc.relation.isversionofhttps://doi.org/10.1007/s11548-019-02032-xen_US
dc.rightsArticle is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.en_US
dc.sourceSpringer International Publishingen_US
dc.titleA “eye-in-body” integrated surgery robot system for stereotactic surgeryen_US
dc.typeArticleen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
dc.eprint.versionAuthor's final manuscripten_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dc.date.updated2020-09-24T21:15:32Z
dc.language.rfc3066en
dc.rights.holderCARS
dspace.embargo.termsY
dspace.date.submission2020-09-24T21:15:32Z
mit.licensePUBLISHER_POLICY
mit.metadata.statusAuthority Work and Publication Information Needed