Image plate multi-scan response to fusion protons in the range of 1–14 MeV

Author(s)
Vanderloo, N; Cufari, M; Russell, L; Johnson, TM; Vargas, J; Foo, BC; Buschmann, BI; Dannhoff, SG; DeVault, A; Evans, TE; Kunimune, JH; Lawrence, Y; Pearcy, JA; Reichelt, BL; Wink, CW; Gatu Johnson, M; Petrasso, RD; Frenje, JA; Li, CK; ... Show more Show less
Thumbnail
DownloadPublished version (4.530Mb)
Publisher with Creative Commons License

Publisher with Creative Commons License

Creative Commons Attribution

Terms of use
Creative Commons Attribution https://creativecommons.org/licenses/by/4.0/
Metadata
Show full item record
Abstract
Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.
Date issued
2024-09-24
URI
https://hdl.handle.net/1721.1/165060
Department
Massachusetts Institute of Technology. Plasma Science and Fusion Center
Journal
Review of Scientific Instruments
Publisher
AIP Publishing
Citation
N. Vanderloo, M. Cufari, L. Russell, T. M. Johnson, J. Vargas, B. C. Foo, B. I. Buschmann, S. G. Dannhoff, A. DeVault, T. E. Evans, J. H. Kunimune, Y. Lawrence, J. A. Pearcy, B. L. Reichelt, C. W. Wink, M. Gatu Johnson, R. D. Petrasso, J. A. Frenje, C. K. Li; Image plate multi-scan response to fusion protons in the range of 1–14 MeV. Rev. Sci. Instrum. 1 September 2024; 95 (9): 093536.
Version: Final published version

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.