Login

The X-ray Microcalorimeter Spectrometer onboard of IXO

Show full item record




Title: The X-ray Microcalorimeter Spectrometer onboard of IXO
Author: den Herder, J. W.; Kelley, R. L.; Mitsuda, K.; Piro, L.; Bandler, S. R.; Bastia, P.; Boyce, K. R.; Bruin, M.; Chervenak, J. A.; Colasanti, L.; Doriese, W. B.; DiPirro, M.; Eckart, M. E.; Ezoe, Y.; Figueroa-Feliciano, E.; Ferrari, L.; Fujimoto, R.; Gatti, F.; Gendreau, K. C.; Gottardi, L.; den Hartog, R.; Hilton, G. C.; Hoevers, H.; Irwin, K. D.; Ishisaki, Y.; Kashani, A.; Kilbourne, C. A.; de Korte, P.; van der Kuur, J.; Macculi, C. ... [more in full view]
Department: Massachusetts Institute of Technology. Dept. of Physics; Kavli Institute for Astrophysics and Space Research
Publisher: Institute of Electrical and Electronics Engineers
Issue Date: 2010-06
Abstract: One of the instruments on the International X-ray Observatory (IXO), under study with NASA, ESA and JAXA, is the X-ray Microcalorimeter Spectrometer (XMS). This instrument, which will provide high spectral resolution images, is based on X-ray micro-calorimeters with Transition Edge Sensor thermometers. The pixels have metallic X-ray absorbers and are read-out by multiplexed SQUID electronics. The requirements for this instrument are demanding. In the central array (40 x 40 pixels) an energy resolution of < 2.5 eV is required, whereas the energy resolution of the outer array is more relaxed (≈ 10 eV) but the detection elements have to be a factor 16 larger in order to keep the number of read-out channels acceptable for a cryogenic instrument. Due to the large collection area of the IXO optics, the XMS instrument must be capable of processing high counting rates, while maintaining the spectral resolution and a low deadtime. In addition, an anti-coincidence detector is required to suppress the particle-induced background. In this paper we will summarize the instrument status and performance. We will describe the results of design studies for the focal plane assembly and the cooling systems. Also the system and its required spacecraft resources will be given.
URI: http://hdl.handle.net/1721.1/61426
ISSN: 0277-786X
Citation: den Herder, J. W. et al. “The x-ray microcalorimeter spectrometer onboard of IXO.” Space Telescopes and Instrumentation 2010: Ultraviolet to Gamma Ray. Ed. Monique Arnaud, Stephen S. Murray, & Tadayuki Takahashi. San Diego, California, USA: SPIE, 2010. 77321H-10. © 2010 SPIE.
Version: Final published version
Terms of Use: Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Published as: http://dx.doi.org/10.1117/12.856018
Journal: Proceedings of SPIE--the International Society for Optical Engineering ; v. 7732

Files in this item

Files Size Format
Downloadable Full Text - application/pdf

This item appears in the following Collection(s)

Show full item record

Search DSpace@MIT


Advanced Search

Browse

My Account

Links