Show simple item record

dc.contributor.authorSharqawy, Mostafa H.
dc.contributor.authorLienhard, John H.
dc.contributor.authorZubair, Syed M.
dc.date.accessioned2012-01-23T16:00:36Z
dc.date.available2012-01-23T16:00:36Z
dc.date.issued2011-04
dc.date.submitted2010-06
dc.identifier.issn0742-4795
dc.identifier.issn1528-8919
dc.identifier.urihttp://hdl.handle.net/1721.1/68628
dc.description.abstractSeawater cooling towers have been used since the 1970s in power generation and other industries, so as to reduce the consumption of freshwater. The salts in seawater are known to create a number of operational problems, including salt deposition, packing blockage, corrosion, and certain environmental impacts from salt drift and blowdown return. In addition, the salinity of seawater affects the thermophysical properties that govern the thermal performance of cooling towers, including vapor pressure, density, specific heat, viscosity, thermal conductivity, and surface tension. In this paper, the thermal performance of seawater cooling towers is investigated using a detailed model of a counterflow wet cooling tower. The model takes into consideration the coupled heat and mass transfer processes and does not make any of the conventional Merkel approximations. In addition, the model incorporates the most up-to-date seawater properties in the literature. The model governing equations are solved numerically, and its validity is checked against the available data in the literature. Based on the results of the model, a correction factor that characterizes the degradation of the cooling tower effectiveness as a function of seawater salinity and temperature approach is presented for performance evaluation purposes.en_US
dc.description.sponsorshipKing Fahd University of Petroleum and Mineralsen_US
dc.description.sponsorshipCenter for Clean Water and Clean Energy at MIT and KFUPMen_US
dc.language.isoen_US
dc.publisherAmerican Society of Mechanical Engineersen_US
dc.relation.isversionofhttp://dx.doi.org/10.1115/1.4002159en_US
dc.rightsCreative Commons Attribution-Noncommercial-Share Alike 3.0en_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/en_US
dc.sourceProf. Lienhard via Angie Locknaren_US
dc.titleOn thermal performance of seawater cooling towersen_US
dc.typeArticleen_US
dc.identifier.citationSharqawy, Mostafa H., John H. Lienhard, and Syed M. Zubair. “On Thermal Performance of Seawater Cooling Towers.” Journal of Engineering for Gas Turbines and Power 133.4 (2011): 043001.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineeringen_US
dc.contributor.approverLienhard, John H.
dc.contributor.mitauthorLienhard, John H.
dc.contributor.mitauthorSharqawy, Mostafa H.
dc.relation.journalJournal of Engineering for Gas Turbines and Poweren_US
dc.eprint.versionAuthor's final manuscripten_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dspace.orderedauthorsSharqawy, Mostafa H.; Lienhard, John H.; Zubair, Syed M.en
dc.identifier.orcidhttps://orcid.org/0000-0002-2901-0638
dc.identifier.orcidhttps://orcid.org/0000-0003-4777-1286
mit.licenseOPEN_ACCESS_POLICYen_US
mit.metadata.statusComplete


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record