Non-descanned multifocal multiphoton microscopy with a multianode photomultiplier tube

Author(s)
Cha, Jae Won; Subramanian, Jaichandar; Nedivi, Elly; So, Peter T. C.; Yew, Yan Seng Elijah; Kim, Daekeun, Ph. D. Massachusetts Institute of Technology; ... Show more Show less
Thumbnail
DownloadSo_Non-descanned.pdf (10.98Mb)
PUBLISHER_POLICY

Publisher Policy

Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.

Terms of use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Metadata
Show full item record
Abstract
Multifocal multiphoton microscopy (MMM) improves imaging speed over a point scanning approach by parallelizing the excitation process. Early versions of MMM relied on imaging detectors to record emission signals from multiple foci simultaneously. For many turbid biological specimens, the scattering of emission photons results in blurred images and degrades the signal-to-noise ratio (SNR). We have recently demonstrated that a multianode photomultiplier tube (MAPMT) placed in a descanned configuration can effectively collect scattered emission photons from each focus into their corresponding anodes significantly improving image SNR for highly scattering specimens. Unfortunately, a descanned MMM has a longer detection path resulting in substantial emission photon loss. Optical design constraints in a descanned geometry further results in significant optical aberrations especially for large field-of-view (FOV), high NA objectives. Here, we introduce a non-descanned MMM based on MAPMT that substantially overcomes most of these drawbacks. We show that we improve signal efficiency up to fourfold with limited image SNR degradation due to scattered emission photons. The excitation foci can also be spaced wider to cover the full FOV of the objective with minimal aberrations. The performance of this system is demonstrated by imaging interneuron morphological structures deep in the brains of living mice.
Date issued
2015-03
URI
http://hdl.handle.net/1721.1/97725
Department
Massachusetts Institute of Technology. Department of Biological Engineering; Massachusetts Institute of Technology. Department of Biology; Massachusetts Institute of Technology. Department of Brain and Cognitive Sciences; Massachusetts Institute of Technology. Department of Mechanical Engineering; Picower Institute for Learning and Memory
Journal
AIP Advances
Publisher
American Institute of Physics (AIP)
Citation
Cha, Jae Won, Elijah Y. S. Yew, Daekeun Kim, Jaichandar Subramanian, Elly Nedivi, and Peter T. C. So. “Non-Descanned Multifocal Multiphoton Microscopy with a Multianode Photomultiplier Tube.” AIP Advances 5, no. 8 (August 2015): 084802.
Version: Final published version
ISSN
2158-3226

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.