MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Speckle reduction in swept source optical coherence tomography images with slow-axis averaging

Author(s)
Tan, Ou; Li, Yan; Wang, Yimin; Kraus, Martin F.; Liu, Jonathan Jaoshin; Baumann, Bernhard; Fujimoto, James G.; Huang, David; Potsaid, Benjamin M.; ... Show more Show less
Thumbnail
DownloadFujimoto_Speckle reduction.pdf (6.243Mb)
PUBLISHER_POLICY

Publisher Policy

Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.

Terms of use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Metadata
Show full item record
Abstract
The effectiveness of speckle reduction using traditional frame averaging technique was limited in ultrahigh speed optical coherence tomography (OCT). As the motion between repeated frames was very small, the speckle pattern of the frames might be identical. This problem could be solved by averaging frames acquired at slightly different locations. The optimized scan range depended on the spot size of the laser beam, the smoothness of the boundary, and the homogeneity of the tissue. In this study we presented a method to average frames obtained within a narrow range along the slow-axis. A swept-source OCT with 100,000 Hz axial scan rate was used to scan the retina in vivo. A series of narrow raster scans (0-50 micron along the slow axis) were evaluated. Each scan contained 20 image frames evenly distributed in the scan range. The imaging frame rate was 417 HZ. Only frames with high correlation after rigid registration were used in averaging. The result showed that the contrast-to-noise ratio (CNR) increased with the scan range. But the best edge reservation was obtained with 15 micron scan range. Thus, for ultrahigh speed OCT systems, averaging frames from a narrow band along the slow-axis could achieve better speckle reduction than traditional frame averaging techniques.
Date issued
2012-02
URI
http://hdl.handle.net/1721.1/100218
Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science; Massachusetts Institute of Technology. Research Laboratory of Electronics
Journal
Proceedings of SPIE--the International Society for Optical Engineering
Publisher
SPIE
Citation
Tan, Ou, Yan Li, Yimin Wang, Martin F. Kraus, Jonathan J. Liu, Benjamin Potsaid, Bernhard Baumann, James G. Fujimoto, and David Huang. “Speckle Reduction in Swept Source Optical Coherence Tomography Images with Slow-Axis Averaging.” Edited by Joseph A. Izatt, James G. Fujimoto, and Valery V. Tuchin. Optical Coherence Tomography and Coherence Domain Optical Methods in Biomedicine XVI (January 30, 2012). © 2012 Society of Photo-Optical Instrumentation Engineers (SPIE).
Version: Final published version
ISSN
0277-786X
1605-7422

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.