Show simple item record

dc.contributor.authorWarsinger, David Elan Martin
dc.contributor.authorSwaminathan, Jaichander
dc.contributor.authorLienhard, John H
dc.date.accessioned2015-12-14T19:41:06Z
dc.date.available2015-12-14T19:41:06Z
dc.date.issued2014-08
dc.identifier.urihttp://hdl.handle.net/1721.1/100241
dc.description.abstractAir gap membrane distillation (AGMD) experiments were performed with varied temperature and varied module inclination angles to characterize the effect of module angle on permeate production and thermal performance. While AGMD is potentially one of the most energy efficient membrane distillation configurations, transport resistances in the air gap typically dominate the thermal performance, resulting in degraded permeate production. Tilting the module away from vertical offers the opportunity to manipulate the condensate layer and its associated thermal resistance. In this study, we report experiments on varying module tilt angle performed with a flat plate AGMD module under fully characterized heat and mass transfer conditions. Numerical modeling is also performed to better understand the experimental results. The tests indicated that the AGMD system behaves as a “permeate gap”, or flooded membrane distillation system for declined and extremely inclined positions. A key finding relevant to all AGMD systems is that at highly negative tilt angles (more than 30 degrees), condensate may fall onto the membrane causing thermal bridging and increased permeate production. Near vertical and positive tilt angles (<15 degrees from vertical) show no significant effect of module tilt on performance, in line with model predictions.en_US
dc.description.sponsorshipMIT Masdar Program (02/MI/MI/CP/11/07633/GEN/G/00)en_US
dc.language.isoen_US
dc.relation.isversionofhttp://www.ihtc-15.org/program.shtmlen_US
dc.rightsCreative Commons Attribution-Noncommercial-Share Alikeen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/en_US
dc.sourceProf. Lienhard via Angie Locknaren_US
dc.titleEFFECT OF MODULE INCLINATION ANGLE ON AIR GAP MEMBRANE DISTILLATIONen_US
dc.typeArticleen_US
dc.identifier.citationWarsinger, David E. M., Jaichander Swaminathan, and John H. Lienhard V. "EFFECT OF MODULE INCLINATION ANGLE ON AIR GAP MEMBRANE DISTILLATION." 15th International Heat Transfer Conference (IHTC-15) (August 2014).en_US
dc.contributor.departmentMassachusetts Institute of Technology. Abdul Latif Jameel World Water & Food Security Laben_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineeringen_US
dc.contributor.mitauthorWarsinger, David Elan Martinen_US
dc.contributor.mitauthorSwaminathan, Jaichanderen_US
dc.contributor.mitauthorLienhard, John H.en_US
dc.relation.journalProceedings of the 15th International Heat Transfer Conference (IHTC-15)en_US
dc.eprint.versionAuthor's final manuscripten_US
dc.type.urihttp://purl.org/eprint/type/ConferencePaperen_US
eprint.statushttp://purl.org/eprint/status/NonPeerRevieweden_US
dspace.orderedauthorsWarsinger, David E. M.; Swaminathan, Jaichander; Lienhard V, John H.en_US
dc.identifier.orcidhttps://orcid.org/0000-0002-2901-0638
dc.identifier.orcidhttps://orcid.org/0000-0001-8375-2694
dc.identifier.orcidhttps://orcid.org/0000-0003-3446-1473
mit.licenseOPEN_ACCESS_POLICYen_US
mit.metadata.statusComplete


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record