Show simple item record

dc.contributor.authorPrakash Narayan, G.
dc.contributor.authorZubair, Syed M.
dc.contributor.authorChehayeb, Karim Malek
dc.contributor.authorLienhard, John H
dc.date.accessioned2016-05-13T19:29:32Z
dc.date.available2016-05-13T19:29:32Z
dc.date.issued2013-10
dc.date.submitted2013-09
dc.identifier.issn00179310
dc.identifier.urihttp://hdl.handle.net/1721.1/102491
dc.description.abstractHumidification dehumidification (HDH) desalination systems are well suited for small scale, off-grid desalination. These systems are very robust and can tolerate a wide range of feed salinities, making them a good candidate for treating produced water from hydraulically fractured natural gas wells. A primary engineering challenge for these systems is their high thermal energy consumption. In this study, we examine the use of multiple air extractions and injections to thermodynamically balance the HDH system, so as to make it more energy efficient. The effect of the number of extractions on several performance parameters is studied. In addition, we study the effect of the enthalpy pinch, which is a measure of performance for a heat and mass exchanger, on these performance parameters. Finally, we present results that can be used as guidelines in designing HDH systems. These results include the identification of appropriate temperatures for the extracted/injected air streams, the division of the heat duty between stages, and the value of the mass flow rate ratio in each stage at various values of enthalpy pinch.en_US
dc.description.sponsorshipCenter for Clean Water and Clean Energy at MIT and KFUPM (Project R4-CW-08)en_US
dc.language.isoen_US
dc.publisherElsevieren_US
dc.relation.isversionofhttp://dx.doi.org/10.1016/j.ijheatmasstransfer.2013.09.025en_US
dc.rightsCreative Commons Attribution-Noncommercial-NoDerivativesen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/en_US
dc.sourceLienhard via Angie Locknaren_US
dc.titleUse of multiple extractions and injections to thermodynamically balance the humidification dehumidification desalination systemen_US
dc.typeArticleen_US
dc.identifier.citationChehayeb, Karim M., G. Prakash Narayan, Syed M. Zubair, and John H. Lienhard. “Use of Multiple Extractions and Injections to Thermodynamically Balance the Humidification Dehumidification Desalination System.” International Journal of Heat and Mass Transfer 68 (January 2014): 422–34.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Abdul Latif Jameel World Water & Food Security Laben_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineeringen_US
dc.contributor.approverLienhard, John H.en_US
dc.contributor.mitauthorChehayeb, Karim Maleken_US
dc.contributor.mitauthorLienhard, John H.en_US
dc.relation.journalInternational Journal of Heat and Mass Transferen_US
dc.eprint.versionAuthor's final manuscripten_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dspace.orderedauthorsChehayeb, Karim M.; Prakash Narayan, G.; Zubair, Syed M.; Lienhard, John H.en_US
dspace.embargo.termsNen_US
dc.identifier.orcidhttps://orcid.org/0000-0003-3559-9167
dc.identifier.orcidhttps://orcid.org/0000-0002-2901-0638
mit.licensePUBLISHER_CCen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)