Experiments and modeling of bubble column dehumidifier performance

Author(s)
Tow, Emily W.; Lienhard, John H
Thumbnail
DownloadBCDH_IJTS_2013.pdf (1.072Mb)
OPEN_ACCESS_POLICY

Open Access Policy

Creative Commons Attribution-Noncommercial-Share Alike

Terms of use
Creative Commons Attribution-Noncommercial-Share Alike http://creativecommons.org/licenses/by-nc-sa/4.0/
Metadata
Show full item record
Abstract
Humidification–dehumidification is a promising technology for decentralized, small-scale desalination, but conventional dehumidifiers are expensive due to the large surface area required. Direct-contact dehumidification in bubble columns has been shown to significantly decrease dehumidifier size and cost. In this paper, the heat flux and parallel-flow effectiveness of a bubble column dehumidifier are investigated experimentally using significantly smaller cooling coils than in previous work. In addition, a model is developed which predicts the heat transfer rate with an average error of less than 3%. It is found that heat flux rises and effectiveness decreases with decreasing coil area. Increasing air flow rate and air temperature both lead to increased heat flux but decreased effectiveness. Neither bubble-on-coil impact nor column height are found to significantly affect heat flux or effectiveness. The conflicting findings of previous research on bubble-on-coil impact are explained by the other trends identified in this work. Modeling results for salt water temperature and tube diameter are presented. Additional heat transfer in the air gap above the column liquid is explored, but found to be minimal for well-designed columns with low temperature pinch. These findings will inform the design of bubble column dehumidifiers for high heat recovery and low capital cost.
Date issued
2014-03
URI
http://hdl.handle.net/1721.1/102493
Department
Massachusetts Institute of Technology. Abdul Latif Jameel World Water & Food Security Lab; Massachusetts Institute of Technology. Department of Mechanical Engineering
Journal
International Journal of Thermal Sciences
Publisher
Elsevier
Citation
Tow, Emily W., and John H. Lienhard. “Experiments and Modeling of Bubble Column Dehumidifier Performance.” International Journal of Thermal Sciences 80 (June 2014): 65–75.
Version: Author's final manuscript
ISSN
12900729

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.