Efficacy of a Device to Narrow the Coronary Sinus in Refractory Angina

Author(s)
Verheye, Stefan; Jolicœur, E. Marc; Behan, Miles W.; Pettersson, Thomas; Sainsbury, Paul; Hill, Jonathan; Vrolix, Mathias; Agostoni, Pierfrancesco; Engstrom, Thomas; Labinaz, Marino; de Silva, Ranil; Schwartz, Marc; Meyten, Nathalie; Uren, Neal G.; Doucet, Serge; Tanguay, Jean-François; Lindsay, Steven; Henry, Timothy D.; White, Christopher J.; Edelman, Elazer R.; Banai, Shmuel; ... Show more Show less
Thumbnail
DownloadEdelman_Efficacy of a device.pdf (653.2Kb)
PUBLISHER_POLICY

Publisher Policy

Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.

Terms of use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Metadata
Show full item record
Abstract
Background: Many patients with coronary artery disease who are not candidates for revascularization have refractory angina despite standard medical therapy. The balloon-expandable, stainless steel, hourglass-shaped, coronary-sinus reducing device creates a focal narrowing and increases pressure in the coronary sinus, thus redistributing blood into ischemic myocardium. Methods: We randomly assigned 104 patients with Canadian Cardiovascular Society (CCS) class III or IV angina (on a scale from I to IV, with higher classes indicating greater limitations on physical activity owing to angina) and myocardial ischemia, who were not candidates for revascularization, to implantation of the device (treatment group) or to a sham procedure (control group). The primary end point was the proportion of patients with an improvement of at least two CCS angina classes at 6 months. Results: A total of 35% of the patients in the treatment group (18 of 52 patients), as compared with 15% of those in the control group (8 of 52), had an improvement of at least two CCS angina classes at 6 months (P=0.02). The device was also associated with improvement of at least one CCS angina class in 71% of the patients in the treatment group (37 of 52 patients), as compared with 42% of those in the control group (22 of 52) (P=0.003). Quality of life as assessed with the use of the Seattle Angina Questionnaire was significantly improved in the treatment group, as compared with the control group (improvement on a 100-point scale, 17.6 vs. 7.6 points; P=0.03). There were no significant between-group differences in improvement in exercise time or in the mean change in the wall-motion index as assessed by means of dobutamine echocardiography. At 6 months, 1 patient in the treatment group had had a myocardial infarction; in the control group, 1 patient had died and 3 had had a myocardial infarction. Conclusions: In this small clinical trial, implantation of the coronary-sinus reducing device was associated with significant improvement in symptoms and quality of life in patients with refractory angina who were not candidates for revascularization.
Date issued
2015-02
URI
http://hdl.handle.net/1721.1/102789
Department
Institute for Medical Engineering and Science
Journal
New England Journal of Medicine
Publisher
New England Journal of Medicine Group
Citation
Verheye, Stefan, E. Marc Jolicœur, Miles W. Behan, Thomas Pettersson, Paul Sainsbury, Jonathan Hill, Mathias Vrolix, et al. “Efficacy of a Device to Narrow the Coronary Sinus in Refractory Angina.” N Engl J Med 372, no. 6 (February 5, 2015): 519–527.
Version: Final published version
ISSN
0028-4793
1533-4406

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.