MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Automatic Cardiac Self-Gating of Small-Animal PET Data

Author(s)
Herraiz, Joaquin L.; Herranz, Elena; Cal-González, Jacobo; Vaquero, Juan J.; Desco, Manuel; Cussó, Lorena; Udias, Jose M.; ... Show more Show less
Thumbnail
Download11307_2015_868_ReferencePDF.pdf (697.7Kb)
PUBLISHER_POLICY

Publisher Policy

Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.

Terms of use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Metadata
Show full item record
Abstract
Purpose The cardiac gating signal (CGS) in positron emission tomography (PET) studies is usually obtained from an electrocardiography (ECG) monitor. In this work, we propose a method to obtain the CGS in small-animal PET using the acquired list-mode data without using any hardware or end-user input. Procedures The CGS was obtained from the number of coincidences over time acquired in the lines-of-response connected with the cardiac region. This region is identified in the image as its value changes with frequencies in the range of 3 to 12 Hz. The procedure was tested in a study with 29 Wistar rats and 6 mice injected with 2-deoxy-2-[[superscript 18]F]fluoro-d-glucose, which underwent a 45-min single-bed list-mode PET scan of the heart syncronized with an ECG. The estimated signals and the reconstructed images using eight-gated frames were compared with the ones obtained using the ECG signal from the monitor. Results The differences of the PET-based CGS with respect to the ECG relative to the duration of the heartbeats were 5.6 % in rats and 11.0 % in mice. The reconstructed gated images obtained from the proposed method do not differ qualitatively with respect to the ones obtained with the ECG. The quantitative analysis of both set of images were performed measuring the volume of the left ventricle (LV) of the rats in the end-of-systole and end-of-diastole phase. The differences found in these parameters between both methods were below 12.1 % in the ESV and 9.3 % in the EDV with a 95 % confidence interval, which are comparable to the accuracy (7 %) of the method used for segmenting the LV. Conclusion The proposed method is able to provide a valid and accurate CGS in small-animal PET list-mode data.
Date issued
2015-06
URI
http://hdl.handle.net/1721.1/103303
Department
Madrid-MIT M+Vision Consortium; Massachusetts Institute of Technology. Research Laboratory of Electronics
Journal
Molecular Imaging and Biology
Publisher
Springer US
Citation
Herraiz, Joaquin L., Elena Herranz, Jacobo Cal-González, Juan J. Vaquero, Manuel Desco, Lorena Cussó, and Jose M. Udias. “Automatic Cardiac Self-Gating of Small-Animal PET Data.” Molecular Imaging and Biology 18, no. 1 (June 9, 2015): 109–116.
Version: Author's final manuscript
ISSN
1536-1632
1860-2002

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.