Time Evolution of Deformation in a Human Cartilage Under Cyclic Loading

Author(s)
Zhang, Lihai; Miramini, Saeed; Smith, David W.; Gardiner, Bruce S.; Grodzinsky, Alan J.
Thumbnail
Download10439_2014_1164_ReferencePDF.pdf (1018.Kb)
OPEN_ACCESS_POLICY

Open Access Policy

Creative Commons Attribution-Noncommercial-Share Alike

Terms of use
Creative Commons Attribution-Noncommercial-Share Alike http://creativecommons.org/licenses/by-nc-sa/4.0/
Metadata
Show full item record
Abstract
Recent imaging has revealed that in vivo contact deformations of human knee cartilage under physiological loadings are surprisingly large—typically on the order of 10%, but up to 20 or 30% of tibiofemora cartilage thickness depending on loading conditions. In this paper we develop a biphasic, large deformation, non-linear poroelastic model of cartilage that can accurately represent the time dependence and magnitude of cyclic cartilage deformations in vivo. The model takes into account cartilage tension–compression nonlinearity and a new constitutive relation in which the compressive stiffness and hydraulic permeability of the cartilage adjusts in response to the strain-dependent aggrecan concentration. The model predictions are validated using experimental test results on osteochondral plugs obtained from human cadavers. We find that model parameters can be optimised to give an excellent fit to the experimental data. Using typical hydraulic conductivity and stiffness parameters for healthy cartilage, we find that the experimentally observed transient and steady state tissue deformations under cyclic loading and unloading can be reproduced by the model. Steady state tissue deformations are shown to cycle between 10% (exudation strain) and 20% (total strain) in response to the cyclic test loads. At steady-state cyclic loading, the pore fluid exuded from the tissue is exactly equal to the pore fluid imbibed by the tissue during each load cycle.
Date issued
2014-10
URI
http://hdl.handle.net/1721.1/103524
Department
Massachusetts Institute of Technology. Center for Biomedical Engineering; Massachusetts Institute of Technology. Department of Biological Engineering; Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science; Massachusetts Institute of Technology. Department of Mechanical Engineering
Journal
Annals of Biomedical Engineering
Publisher
Springer US
Citation
Zhang, Lihai, Saeed Miramini, David W. Smith, Bruce S. Gardiner, and Alan J. Grodzinsky. “Time Evolution of Deformation in a Human Cartilage Under Cyclic Loading.” Ann Biomed Eng 43, no. 5 (October 21, 2014): 1166–1177.
Version: Author's final manuscript
ISSN
0090-6964
1573-9686

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.