MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Assessment of colorimetric amplification methods in a paper-based immunoassay for diagnosis of malaria

Author(s)
Lathwal, Shefali; Sikes, Hadley
Thumbnail
DownloadSikes_Assessment of.pdf (5.649Mb)
PUBLISHER_CC

Publisher with Creative Commons License

Creative Commons Attribution

Terms of use
Creative Commons Attribution-NonCommercial 3.0 Unported licence http://creativecommons.org/licenses/by-nc/3.0/
Metadata
Show full item record
Abstract
Colorimetric detection methods that produce results readable by eye are important for diagnostic tests in resource-limited settings. In this work, we have compared three main types of colorimetric methods – enzymatic reactions, silver deposition catalyzed by gold nanoparticles, and polymerization-based amplification – in a paper-based immunoassay for detection of Plasmodium falciparum histidine-rich protein 2, a biomarker of malarial infection. We kept the binding events in the immunoassay constant in order to isolate the effect of the detection method on the outcome of the test. We have highlighted that the optimal readout time in a test can vary significantly – ranging from immediately after addition of a visualization agent to 25 minutes after addition of a visualization agent – depending on the colorimetric method being used, and accurate time keeping is essential to prevent false positives in methods where substantial color develops over time in negative tests. We have also shown that the choice of a colorimetric method impacts the calculated limit-of-detection, the ease of visual perception of the readout, and the total cost of the assay, and therefore directly impacts the feasibility and the ease-of-use of a test in field settings.
Date issued
2016-04
URI
http://hdl.handle.net/1721.1/103541
Department
Massachusetts Institute of Technology. Department of Chemical Engineering
Journal
Lab on a Chip
Publisher
Royal Society of Chemistry
Citation
Lathwal, Shefali, and Hadley D. Sikes. “Assessment of Colorimetric Amplification Methods in a Paper-Based Immunoassay for Diagnosis of Malaria.” Lab on a Chip 16, no. 8 (2016): 1374–1382.
Version: Final published version
ISSN
1473-0197
1473-0189

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.