MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Supernumerary Robotic Fingers as a Therapeutic Device for Hemiparetic Patients

Author(s)
Ort, Moses Teddy; Wu, Faye Y; Hensel, Nicholas Charles; Asada, Haruhiko
Thumbnail
DownloadAsada_Supernumerary robotic.pdf (2.136Mb)
PUBLISHER_POLICY

Publisher Policy

Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.

Terms of use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Metadata
Show full item record
Abstract
Patients with hemiparesis often have limited functionality in the left or right hand. The standard therapeutic approach requires the patient to attempt to make use of the weak hand even though it is not functionally capable, which can result in feelings of frustration. Furthermore, hemiparetic patients also face challenges in completing many bimanual tasks, for example walker manipulation, that are critical to patients’ independence and quality of life. A prototype therapeutic device with two supernumerary robotic fingers was used to determine if robotic fingers could functionally assist a human in the performance of bimanual tasks by observing the pose of the healthy hand. Specific focus was placed on the identification of a straightforward control routine which would allow a patient to carry out simple manipulation tasks with some intermittent input from a therapist. Part of this routine involved allowing a patient to switch between active and inactive monitoring of hand position, resulting in additional manipulation capabilities. The prototype successfully enabled a test subject to complete various bimanual tasks using the robotic fingers in place of normal hand motions. From these results, it is clear that the device could allow a hemiparetic patient to complete tasks which would previously have been impossible to perform.
Date issued
2015-10
URI
http://hdl.handle.net/1721.1/107262
Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Journal
Proceedings of the ASME 2015 Dynamic Systems and Control Conference
Publisher
ASME International
Citation
Ort, Teddy et al. “Supernumerary Robotic Fingers as a Therapeutic Device for Hemiparetic Patients.” ASME, 2015. V002T27A010. © 2015 by ASME
Version: Final published version
ISBN
978-0-7918-5725-0

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.