Show simple item record

dc.contributor.authorCosta, Luca
dc.contributor.authorAndriatis, Alexander
dc.contributor.authorBrennich, Martha
dc.contributor.authorTeulon, Jean-Marie
dc.contributor.authorChen, Shu-wen W.
dc.contributor.authorPellequer, Jean-Luc
dc.contributor.authorRound, Adam
dc.date.accessioned2017-04-07T17:26:48Z
dc.date.available2017-04-07T17:26:48Z
dc.date.issued2016-10
dc.date.submitted2016-06
dc.identifier.issn1472-6807
dc.identifier.urihttp://hdl.handle.net/1721.1/107945
dc.description.abstractBackground Synchrotron radiation facilities are pillars of modern structural biology. Small-Angle X-ray scattering performed at synchrotron sources is often used to characterize the shape of biological macromolecules. A major challenge with high-energy X-ray beam on such macromolecules is the perturbation of sample due to radiation damage. Results By employing atomic force microscopy, another common technique to determine the shape of biological macromolecules when deposited on flat substrates, we present a protocol to evaluate and characterize consequences of radiation damage. It requires the acquisition of images of irradiated samples at the single molecule level in a timely manner while using minimal amounts of protein. The protocol has been tested on two different molecular systems: a large globular tetremeric enzyme (β-Amylase) and a rod-shape plant virus (tobacco mosaic virus). Radiation damage on the globular enzyme leads to an apparent increase in molecular sizes whereas the effect on the long virus is a breakage into smaller pieces resulting in a decrease of the average long-axis radius. Conclusions These results show that radiation damage can appear in different forms and strongly support the need to check the effect of radiation damage at synchrotron sources using the presented protocol.en_US
dc.publisherBiomed Central Ltd.en_US
dc.relation.isversionofhttp://dx.doi.org/10.1186/s12900-016-0068-2en_US
dc.rightsCreative Commons Attributionen_US
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/en_US
dc.sourceBioMed Centralen_US
dc.titleCombined small angle X-ray solution scattering with atomic force microscopy for characterizing radiation damage on biological macromoleculesen_US
dc.typeArticleen_US
dc.identifier.citationCosta, Luca et al. “Combined Small Angle X-Ray Solution Scattering with Atomic Force Microscopy for Characterizing Radiation Damage on Biological Macromolecules.” BMC Structural Biology 16.1 (2016): n. pag.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Physicsen_US
dc.contributor.mitauthorAndriatis, Alexander
dc.relation.journalBMC Structural Biologyen_US
dc.eprint.versionFinal published versionen_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dc.date.updated2016-10-28T04:31:05Z
dc.language.rfc3066en
dc.rights.holderThe Author(s)
dspace.orderedauthorsCosta, Luca; Andriatis, Alexander; Brennich, Martha; Teulon, Jean-Marie; Chen, Shu-wen W.; Pellequer, Jean-Luc; Round, Adamen_US
dspace.embargo.termsNen_US
mit.licensePUBLISHER_CCen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record