Impact of Equivalence Ratio on the Macrostructure of Premixed Swirling CH[subscript 4]/Air and CH[subscript 4]/O[subscript 2]/CO[subscript 2] Flames
Author(s)
Watanabe, Hirotatsu; Shanbhogue, Santosh J.; Ghoniem, Ahmed F.; Shanbhogue, Santosh; Ghoniem, Ahmed F
DownloadGhoniem_Impact of.pdf (1.805Mb)
PUBLISHER_POLICY
Publisher Policy
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Alternative title
Impact of Equivalence Ratio on the Macrostructure of Premixed Swirling CH4/Air and CH4/O2/CO2 Flames
Terms of use
Metadata
Show full item recordAbstract
Premixed CH[subscript 4]/O[subscript 2]/CO[subscript 2] flames (oxy-flames) and CH[subscript 4]/air flames (air-flames) were experimentally studied in a swirl-stabilized combustor. For comparing oxy and air flames, the same equivalence ratio and adiabatic flame temperature were used. CO[subscript 2] dilution was adjusted to attain the same adiabatic temperature for the oxy-flame and the corresponding air-flame while keeping the equivalence ratio and Reynolds number (=20,000) the same. For high equivalence ratios, we observed flames stabilized along the inner and outer shear layers of the swirling flow and sudden expansion, respectively, in both flames. However, one notable difference between the two flames appears as the equivalence ratio reaches 0.60. At this point, the outer shear layer flame disappears in the air-flame while it persists in the oxy-flame, despite the lower burning velocity of the oxy-flame. Prior PIV measurements (Ref. 9) showed that the strains along the outer shear layer are higher than along the inner shear layer. Therefore, the extinction strain rates in both flames were calculated using a counter-flow premixed twin flame configuration. Calculations at the equivalence ratio of 0.60 show that the extinction strain rate is higher in the oxy than in the air flame, which help explain why it persists on the outer shear layer with higher strain rate. It is likely that extinction strain rates contribute to the oxy-flame stabilization when air flame extinguish in the outer shear layer. However, the trend reverses at higher equivalence ratio, and the cross point of the extinction strain rate appears at equivalence ratio of 0.64.
Date issued
2015-06Department
Massachusetts Institute of Technology. Department of Mechanical EngineeringJournal
Proceedings of ASME Turbo Expo 2015: Turbine Technical Conference and Exposition GT2015
Publisher
American Society of Mechanical Engineers (ASME)
Citation
Watanabe, Hirotatsu, Santosh J. Shanbhogue, and Ahmed F. Ghoniem. “Impact of Equivalence Ratio on the Macrostructure of Premixed Swirling CH [subscript 4]/Air and CH[subscript 4]/O[subscript 2]/CO[subscript 2] Flames.” ASME Turbo Expo 2015: Turbine Technical Conference and Exposition, 15-19 June, 2015, Montréal, Canada , ASME, 2015.
Version: Final published version
ISBN
978-0-7918-5669-7