Show simple item record

dc.contributor.authorKhalifa, Atia E.
dc.contributor.authorBen-Mansour, Rached
dc.contributor.authorYoucef-Toumi, Kamal
dc.contributor.authorChoi, Changrak
dc.date.accessioned2017-05-04T13:49:05Z
dc.date.available2017-05-04T13:49:05Z
dc.date.issued2011-11
dc.identifier.isbn978-0-7918-5494-5
dc.identifier.urihttp://hdl.handle.net/1721.1/108658
dc.description.abstractThis paper presents experimental observations on the characteristics of the acoustic signal propagation and attenuation inside water-filled pipes. An acoustic source (exciter) is mounted on the internal pipe wall, at a fixed location, and produces a tonal sound to simulate a leak noise with controlled frequency and amplitude, under different flow conditions. A hydrophone is aligned with the pipe centerline and can be re-positioned to capture the acoustic signal at different locations. Results showed that the wave attenuation depends on the source frequency and the line pressure. High frequency signals get attenuated more with increasing distance from the source. The optimum location to place the hydrophone for capturing the acoustic signal is not at the vicinity of source location. The optimum location also depends on the frequency and line pressure. It was also observed that the attenuation of the acoustic waves is higher in more flexible pipes like PVC ones.en_US
dc.description.sponsorshipCenter for Clean Water and Clean Energy at MIT and KFUPMen_US
dc.language.isoen_US
dc.publisherAmerican Society of Mechanical Engineers (ASME)en_US
dc.relation.isversionofhttp://dx.doi.org/10.1115/IMECE2011-62333en_US
dc.rightsArticle is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.en_US
dc.sourceAmerican Society of Mechanical Engineers (ASME)en_US
dc.titleCharacterization of In-Pipe Acoustic Wave for Water Leak Detectionen_US
dc.typeArticleen_US
dc.identifier.citationKhalifa, Atia E. et al. “Characterization of In-Pipe Acoustic Wave for Water Leak Detection.” ASME 2011 International Mechanical Engineering Congress and Exposition, 11-17 November, 2011, Denver, Colorado, USA, ASME, 2011.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineeringen_US
dc.contributor.mitauthorYoucef-Toumi, Kamal
dc.contributor.mitauthorChoi, Changrak
dc.relation.journalProceedings of the ASME 2011 International Mechanical Engineering Congress & Exposition IMECE2011en_US
dc.eprint.versionFinal published versionen_US
dc.type.urihttp://purl.org/eprint/type/ConferencePaperen_US
eprint.statushttp://purl.org/eprint/status/NonPeerRevieweden_US
dspace.orderedauthorsKhalifa, Atia E.; Ben-Mansour, Rached; Youcef-Toumi, Kamal; Choi, Changraken_US
dspace.embargo.termsNen_US
dc.identifier.orcidhttps://orcid.org/0000-0002-0209-0279
mit.licensePUBLISHER_POLICYen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record