A Novel Point-of-Care Smartphone Based System for Monitoring the Cardiac and Respiratory Systems

Author(s)
Sohn, Kwanghyun; Merchant, Faisal M.; Sayadi, Omid; Puppala, Dheeraj; Doddamani, Rajiv; Sahani, Ashish; Singh, Jagmeet P.; Heist, E. Kevin; Isselbacher, Eric M.; Armoundas, Antonis; ... Show more Show less
Thumbnail
DownloadA novel point-of-care.pdf (1.100Mb)
PUBLISHER_CC

Publisher with Creative Commons License

Creative Commons Attribution

Terms of use
Creative Commons Attribution 4.0 International License http://creativecommons.org/licenses/by/4.0/
Metadata
Show full item record
Abstract
Cardio-respiratory monitoring is one of the most demanding areas in the rapidly growing, mobile-device, based health care delivery. We developed a 12-lead smartphone-based electrocardiogram (ECG) acquisition and monitoring system (called “cvrPhone”), and an application to assess underlying ischemia, and estimate the respiration rate (RR) and tidal volume (TV) from analysis of electrocardiographic (ECG) signals only. During in-vivo swine studies (n = 6), 12-lead ECG signals were recorded at baseline and following coronary artery occlusion. Ischemic indices calculated from each lead showed statistically significant (p < 0.05) increase within 2 min of occlusion compared to baseline. Following myocardial infarction, spontaneous ventricular tachycardia episodes (n = 3) were preceded by significant (p < 0.05) increase of the ischemic index ~1–4 min prior to the onset of the tachy-arrhythmias. In order to assess the respiratory status during apnea, the mechanical ventilator was paused for up to 2 min during normal breathing. We observed that the RR and TV estimation algorithms detected apnea within 7.9 ± 1.1 sec and 5.5 ± 2.2 sec, respectively, while the estimated RR and TV values were 0 breaths/min and less than 100 ml, respectively. In conclusion, the cvrPhone can be used to detect myocardial ischemia and periods of respiratory apnea using a readily available mobile platform.
Date issued
2017-03
URI
http://hdl.handle.net/1721.1/110077
Department
Massachusetts Institute of Technology. Institute for Medical Engineering & Science
Journal
Scientific Reports
Publisher
Nature Publishing Group
Citation
Sohn, Kwanghyun; Merchant, Faisal M.; Sayadi, Omid; Puppala, Dheeraj; Doddamani, Rajiv; Sahani, Ashish; Singh, Jagmeet P.; Heist, E. Kevin; Isselbacher, Eric M. and Armoundas, Antonis A. “A Novel Point-of-Care Smartphone Based System for Monitoring the Cardiac and Respiratory Systems.” Scientific Reports 7 (March 2017): 44946 © 2017 The Author(s)
Version: Final published version
ISSN
2045-2322

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.