Show simple item record

dc.contributor.authorAlcain, E.
dc.contributor.authorMontemayor, A. S.
dc.contributor.authorRozenholc, Y.
dc.contributor.authorLopez Herraiz, Joaquin
dc.contributor.authorHernandez-Tamames, J. A.
dc.contributor.authorAdalsteinsson, Elfar
dc.contributor.authorWald, Lawrence
dc.contributor.authorMalpica, N.
dc.contributor.authorTorrado-Carvajal, A.
dc.date.accessioned2017-07-17T15:35:54Z
dc.date.available2017-07-17T15:35:54Z
dc.date.issued2015-11
dc.identifier.issn0277-786X
dc.identifier.issn1996-756X
dc.identifier.urihttp://hdl.handle.net/1721.1/110724
dc.description.abstractMRI-based bone segmentation is a challenging task because bone tissue and air both present low signal intensity on MR images, making it difficult to accurately delimit the bone boundaries. However, estimating bone from MRI images may allow decreasing patient ionization by removing the need of patient-specific CT acquisition in several applications. In this work, we propose a fast GPU-based pseudo-CT generation from a patient-specific MRI T1-weighted image using a group-wise patch-based approach and a limited MRI and CT atlas dictionary. For every voxel in the input MR image, we compute the similarity of the patch containing that voxel with the patches of all MR images in the database, which lie in a certain anatomical neighborhood. The pseudo-CT is obtained as a local weighted linear combination of the CT values of the corresponding patches. The algorithm was implemented in a GPU. The use of patch-based techniques allows a fast and accurate estimation of the pseudo-CT from MR T1-weighted images, with a similar accuracy as the patient-specific CT. The experimental normalized cross correlation reaches 0.9324±0.0048 for an atlas with 10 datasets. The high NCC values indicate how our method can accurately approximate the patient-specific CT. The GPU implementation led to a substantial decrease in computational time making the approach suitable for real applications.en_US
dc.language.isoen_US
dc.publisherSociety of Photo-Optical Instrumentation Engineers (SPIE)en_US
dc.relation.isversionofhttp://dx.doi.org/10.1117/12.2210963en_US
dc.rightsArticle is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.en_US
dc.sourceSPIEen_US
dc.titleFast pseudo-CT synthesis from MRI T1-weighted images using a patch-based approachen_US
dc.typeArticleen_US
dc.identifier.citationTorrado-Carvajal, A. et al. “Fast Pseudo-CT Synthesis from MRI T1-Weighted Images Using a Patch-Based Approach.” Proceedings of SPIE, 11th International Symposium on Medical Information Processing and Analysis, Cuenca, Ecuador, 17, November, 2015. Vol. 9681. Edited by Eduardo Romero et al., SPIE, 2015. n.p. © 2015 SPIEen_US
dc.contributor.departmentMadrid-MIT M+Visión Consortiumen_US
dc.contributor.departmentHarvard-MIT Program in Health Sciences and Technologyen_US
dc.contributor.departmentMassachusetts Institute of Technology. Research Laboratory of Electronicsen_US
dc.contributor.mitauthorLopez Herraiz, Joaquin
dc.contributor.mitauthorHernandez-Tamames, J. A.
dc.contributor.mitauthorAdalsteinsson, Elfar
dc.contributor.mitauthorWald, Lawrence
dc.contributor.mitauthorMalpica, N.
dc.contributor.mitauthorTorrado-Carvajal, A.
dc.relation.journalProceedings of SPIE--the Society of Photo-Optical Instrumentation Engineersen_US
dc.eprint.versionFinal published versionen_US
dc.type.urihttp://purl.org/eprint/type/ConferencePaperen_US
eprint.statushttp://purl.org/eprint/status/NonPeerRevieweden_US
dspace.orderedauthorsTorrado-Carvajal, A.; Alcain, E.; Montemayor, A. S.; Herraiz, J. L.; Rozenholc, Y.; Hernandez-Tamames, J. A.; Adalsteinsson, E.; Wald, L. L.; Malpica, N.en_US
dspace.embargo.termsNen_US
dc.identifier.orcidhttps://orcid.org/0000-0001-7208-8863
dc.identifier.orcidhttps://orcid.org/0000-0002-7637-2914
mit.licensePUBLISHER_POLICYen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record