Show simple item record

dc.contributor.authorBionta, R. M.
dc.contributor.authorCasey, D. T.
dc.contributor.authorCaggiano, J. A.
dc.contributor.authorHatarik, R.
dc.contributor.authorKhater, H. Y.
dc.contributor.authorSayre, D. B.
dc.contributor.authorKnauer, J. P.
dc.contributor.authorSangster, T. C.
dc.contributor.authorHerrmann, H. W.
dc.contributor.authorKilkenny, J. D.
dc.contributor.authorGatu Johnson, Maria
dc.contributor.authorFrenje, Johan A
dc.contributor.authorLi, C. K.
dc.contributor.authorSeguin, Fredrick Hampton
dc.contributor.authorPetrasso, Richard D
dc.date.accessioned2017-09-08T19:31:26Z
dc.date.available2017-09-08T19:31:26Z
dc.date.issued2014-07
dc.date.submitted2014-05
dc.identifier.issn0034-6748
dc.identifier.issn1089-7623
dc.identifier.urihttp://hdl.handle.net/1721.1/111163
dc.description.abstractThe Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facility (NIF) measures the neutron spectrum in the energy range of 4–20 MeV. This paper describes MRS measurements of DT-fuel and CH-ablator ρR in DT gas-filled symmetry-capsule implosions at the NIF. DT-fuel ρR's of 80–140 mg/cm² and CH-ablator ρR's of 400–680 mg/cm² are inferred from MRS data. The measurements were facilitated by an improved correction of neutron-induced background in the low-energy part of the MRS spectrum. This work demonstrates the accurate utilization of the complete MRS-measured neutron spectrum for diagnosing NIF DT implosions.en_US
dc.description.sponsorshipUnited States. Department of Energy (Contract DE-NA0001857)en_US
dc.language.isoen_US
dc.publisherAmerican Institute of Physics (AIP)en_US
dc.relation.isversionofhttp://dx.doi.org/10.1063/1.4886418en_US
dc.rightsArticle is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.en_US
dc.sourceMIT Plasma Science & Fusion Centeren_US
dc.titleMeasurements of fuel and ablator ρR in Symmetry-Capsule implosions with the Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facilityen_US
dc.typeArticleen_US
dc.identifier.citationGatu Johnson, M. et al. “Measurements of Fuel and Ablator ρR in Symmetry-Capsule Implosions with the Magnetic Recoil Neutron Spectrometer (MRS) on the National Ignition Facility.” Review of Scientific Instruments 85, 11 (November 2014): 11E104 © 2014 American Institute of Physics (AIP)en_US
dc.contributor.departmentMassachusetts Institute of Technology. Plasma Science and Fusion Centeren_US
dc.contributor.mitauthorGatu Johnson, Maria
dc.contributor.mitauthorFrenje, Johan A
dc.contributor.mitauthorLi, C. K.
dc.contributor.mitauthorSeguin, Fredrick Hampton
dc.contributor.mitauthorPetrasso, Richard D
dc.relation.journalReview of Scientific Instrumentsen_US
dc.eprint.versionAuthor's final manuscripten_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dspace.orderedauthorsGatu Johnson, M.; Frenje, J. A.; Li, C. K.; Séguin, F. H.; Petrasso, R. D.; Bionta, R. M.; Casey, D. T.; Caggiano, J. A.; Hatarik, R.; Khater, H. Y.; Sayre, D. B.; Knauer, J. P.; Sangster, T. C.; Herrmann, H. W.; Kilkenny, J. D.en_US
dspace.embargo.termsNen_US
dc.identifier.orcidhttps://orcid.org/0000-0002-1020-3501
mit.licensePUBLISHER_POLICYen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record