Fully automated lumen segmentation of intracoronary optical coherence tomography images

Author(s)
Galon, Micheli Zanotti; Lopes, Augusto Celso; Lemos, Pedro Alves; Athanasiou, Lampros; Rikhtegar Nezami, Farhad; Edelman, Elazer R; ... Show more Show less
Thumbnail
Download101332I.pdf (4.146Mb)
PUBLISHER_POLICY

Publisher Policy

Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.

Terms of use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Metadata
Show full item record
Abstract
Optical coherence tomography (OCT) provides high-resolution cross-sectional images of arterial luminal morphology. Traditionally lumen segmentation of OCT images is performed manually by expert observers; a laborious, time consuming effort, sensitive to inter-observer variability process. Although several automated methods have been developed, the majority cannot be applied in real time because of processing demands. To address these limitations we propose a new method for rapid image segmentation of arterial lumen borders using OCT images that involves the following steps: 1) OCT image acquisition using the raw OCT data, 2) reconstruction of longitudinal cross-section (LOCS) images from four different acquisition angles, 3) segmentation of the LOCS images and 4) lumen contour construction in each 2D cross-sectional image. The efficiency of the developed method was evaluated using 613 annotated images from 10 OCT pullbacks acquired from 10 patients at the time of coronary arterial interventions. High Pearson's correlation coefficient was obtained when lumen areas detected by the method were compared to areas annotated by experts (r=0.98, R 2 =0.96); Bland-Altman analysis showed no significant bias with good limits of agreement. The proposed methodology permits reliable border detection especially in lumen areas having artifacts and is faster than traditional techniques making it capable of being used in real time applications. The method is likely to assist in a number of research and clinical applications - further testing in an expanded clinical arena will more fully define the limits and potential of this approach.
Date issued
2017-02
URI
http://hdl.handle.net/1721.1/112763
Department
Institute for Medical Engineering and Science; Harvard University--MIT Division of Health Sciences and Technology
Journal
Proceedings of SPIE--the Society of Photo-Optical Instrumentation Engineers
Publisher
SPIE
Citation
L. S. Athanasiou et al. "Fully automated lumen segmentation of intracoronary optical coherence tomography images," Proceedings of SPIE 10133, Medical Imaging 2017: Image Processing, Orlando, Florida, United States, 24 February 2017, SPIE. © 2017 SPIE
Version: Final published version
ISSN
0277-786X
1996-756X

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.