dc.contributor.authorLienhard, John H.
dc.contributor.authorWei, Quantum J.
dc.contributor.authorMcGovern, Ronan Killian
dc.date.accessioned2018-06-12T15:08:20Z
dc.date.available2018-06-12T15:08:20Z
dc.date.issued2017-07
dc.date.submitted2017-03
dc.identifier.issn2053-1400
dc.identifier.issn2053-1419
dc.identifier.urihttp://hdl.handle.net/1721.1/116253
dc.description.abstractIn a two-stage reverse osmosis (RO) system of finite size, there are two degrees of freedom not present in a single-stage RO system: distribution of RO elements between the two stages (system design), and feed pressures (system operation). In this study, we investigate the optimal system design and operation of a two-stage RO system with a mass-balance model and establish a lower bound for the energy savings achieved by the optimized two-stage system compared to a single-stage system. A two-stage RO system may consume more or less energy than a single-stage RO system of the same size and freshwater productivity, depending on the first-stage feed pressure and second-stage feed pressure. To minimize energy consumption, feed pressures should be chosen to minimize spatial variance in flux. The optimal element configuration places at least half the elements in the first stage; the exact configuration depends on feed salinity, recovery ratio, and membrane permeability. The greatest energy savings are achieved with a two-stage RO system that has both optimal element configuration and feed pressures. More energy can be saved by adding a stage when the thermodynamic least work of separation is larger. For a given feed salinity, energy savings from adding a second stage grow as recovery ratio increases. Brackish water feeds must be taken to high recovery ratios to achieve substantial energy savings; comparable savings can be achieved at lower recovery ratios for higher salinity feeds. We find that significant energy can be saved with the simplest two-stage RO design, at a system flux similar to today's RO plants and accounting for the effects of concentration polarization.en_US
dc.description.sponsorshipKing Fahd University of Petroleum and Minerals (project number R15-CW-11)en_US
dc.language.isoen_US
dc.publisherRoyal Society of Chemistry (Great Britain)en_US
dc.relation.isversionofhttp://dx.doi.org/10.1039/c7ew00069cen_US
dc.rightsCreative Commons Attribution-Noncommercial-Share Alikeen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/en_US
dc.sourceQ. J. Weien_US
dc.titleSaving energy with an optimized two-stage reverse osmosis systemen_US
dc.typeArticleen_US
dc.identifier.citationWei, Quantum J., Ronan K. McGovern, and John H. Lienhard V. “Saving Energy with an Optimized Two-Stage Reverse Osmosis System.” Environmental Science: Water Research & Technology 3, no. 4 (2017): 659–670.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineeringen_US
dc.contributor.approverWei, Quantum J.en_US
dc.contributor.mitauthorWei, Quantum J.
dc.contributor.mitauthorMcGovern, Ronan Killian
dc.contributor.mitauthorLienhard, John H.
dc.relation.journalEnvironmental Science: Water Research & Technologyen_US
dc.eprint.versionAuthor's final manuscripten_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dspace.orderedauthorsWei, Quantum J.; McGovern, Ronan K.; Lienhard V, John H.en_US
dspace.embargo.termsNen_US
dc.identifier.orcidhttps://orcid.org/0000-0001-5087-1312
dc.identifier.orcidhttps://orcid.org/0000-0002-3808-8824
mit.licenseOPEN_ACCESS_POLICYen_US