Optimized Computer-Aided Segmentation and Three-Dimensional Reconstruction Using Intracoronary Optical Coherence Tomography

Author(s)
Athanasiou, Lambros; Nezami, Farhad Rikhtegar; Galon, Micheli Zanotti; Lopes, Augusto Celso; Lemos, Pedro Alves; De La Torre Hernandez, Jose Maria; Ben Assa, Eyal Benjamin; Edelman, Elazer R; ... Show more Show less
Thumbnail
Downloadieee_acc_final.pdf (1.402Mb)
OPEN_ACCESS_POLICY

Open Access Policy

Creative Commons Attribution-Noncommercial-Share Alike

Terms of use
Creative Commons Attribution-Noncommercial-Share Alike http://creativecommons.org/licenses/by-nc-sa/4.0/
Metadata
Show full item record
Abstract
We present a novel and time-efficient method for intracoronary lumen detection, which produces three-dimensional (3-D) coronary arteries using optical coherence tomographic (OCT) images. OCT images are acquired for multiple patients and longitudinal cross-section (LOCS) images are reconstructed using different acquisition angles. The lumen contours for each LOCS image are extracted and translated to 2-D cross-sectional images. Using two angiographic projections, the centerline of the coronary vessel is reconstructed in 3-D, and the detected 2-D contours are transformed to 3-D and placed perpendicular to the centerline. To validate the proposed method, 613 manual annotations from medical experts were used as gold standard. The 2-D detected contours were compared with the annotated contours, and the 3-D reconstructed models produced using the detected contours were compared to the models produced by the annotated contours. Wall shear stress (WSS), as dominant hemodynamics factor, was calculated using computational fluid dynamics and 844 consecutive 2-mm segments of the 3-D models were extracted and compared with each other. High Pearson's correlation coefficients were obtained for the lumen area (r = 0.98) and local WSS (r = 0.97) measurements, while no significant bias with good limits of agreement was shown in the Bland-Altman analysis. The overlapping and nonoverlapping areas ratio between experts' annotations and presented method was 0.92 and 0.14, respectively. The proposed computer-aided lumen extraction and 3-D vessel reconstruction method is fast, accurate, and likely to assist in a number of research and clinical applications.
Date issued
2018-08-13
URI
http://hdl.handle.net/1721.1/117349
Department
Institute for Medical Engineering and Science
Journal
IEEE Journal of Biomedical and Health Informatics
Publisher
Institute of Electrical and Electronics Engineers (IEEE)
Citation
Athanasiou, Lambros et al. “Optimized Computer-Aided Segmentation and Three-Dimensional Reconstruction Using Intracoronary Optical Coherence Tomography.” IEEE Journal of Biomedical and Health Informatics 22, 4 (July 2018): 1168–1176 © 2013 IEEE
Version: Author's final manuscript
ISSN
2168-2194
2168-2208

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.