Development and Characterization of a Loop Heat Pipe With a Planar Evaporator and Condenser
Author(s)
Kariya, Harumichi Arthur; Hanks, Daniel Frank; Peters, Teresa B.; Brisson II, John G; Wang, Evelyn
Download857_1.pdf (587.0Kb)
PUBLISHER_POLICY
Publisher Policy
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Terms of use
Metadata
Show full item recordAbstract
We present the development and characterization of an air-cooled loop heat pipe with a planar evaporator and condenser. The condenser is mounted vertically above the evaporator, and impellers are integrated both sides of the condenser with tight clearance. The planar geometry allows for effective convective cooling by increasing the surface area and the convective heat transfer coefficient. To ensure condensation across the area of the condenser, a wicking structure is integrated in the condenser. The evaporator incorporates a multi-layer wicking structure to maintain a thermal gradient between the vapor and liquid regions, which is used to sustain the vapor and liquid pressures necessary for operation. The loop heat pipe was demonstrated to remove 140 W of heat at a temperature difference between the evaporator base and inlet air of 50 °C. This work is the first step towards the development of an air-cooled, multiple-condenser loop heat pipe.
Date issued
2011-11Department
Massachusetts Institute of Technology. Department of Mechanical EngineeringJournal
Proceedings of the ASME 2011 International Mechanical Engineering Congress & Exposition
Publisher
ASME International
Citation
Kariya, H. Arthur, et al. “Development and Characterization of a Loop Heat Pipe With a Planar Evaporator and Condenser.” Proceedings of the ASME 2011 International Mechanical Engineering Congress & Exposition, 11-17 November, 2011, Denver, Colorado, ASME, 2011, pp. 857–62. © 2011 by ASME
Version: Final published version
ISBN