Show simple item record

dc.contributor.authorBean, Jonathan F.
dc.contributor.authorCulpepper, Martin L.
dc.contributor.authorSung, Edward
dc.contributor.authorSlocum Jr., Alexander H
dc.contributor.authorMa, Raymond R
dc.date.accessioned2019-01-15T18:28:54Z
dc.date.available2019-01-15T18:28:54Z
dc.date.issued2011-01
dc.date.submitted2010-10
dc.identifier.issn19320-6181
dc.identifier.urihttp://hdl.handle.net/1721.1/120063
dc.description.abstractIn this paper, we present the design, analysis, and testing of an ankle rehabilitation device (ARD), the purpose of which is to improve the efficacy of ankle joint complex (AJC) injury diagnosis and treatment. The ARD enables physicians to quantitatively measure the severity of an injury. This is done by measuring deficiencies in the joint's range of motion, as well as force, torque, and power output. Evaluation of the relative degree of recovery over time can also reduce the error associated with current methodologies for rehabilitation, which rely on measurements based on the patient's verbal response. A Wheatstone bridge circuit is used for the measurement of the various parameters as applied to the blades of complementary rotational flexures; the device is designed to measure motion about three axes of rotation in the ankle joint: pitch, roll, and yaw. A full bridge circuit is applied to each axis of rotation, and the use of multiple axes increases anatomically accurate measurement, enabling characterization of coupled motions. The device has flexibility and a range of motion such that it can be adjusted to take measurements of multiple different degrees of plantar or dorsiflexion of the AJC. The ARD is able to measure both range of motion, force, and torque output simultaneously. Experimental results show that there is significant coupled motion among the ankle joint rotations but that it is highly dependent on a subject's own physical development.en_US
dc.publisherASME Internationalen_US
dc.relation.isversionofhttp://dx.doi.org/10.1115/1.4002901en_US
dc.rightsArticle is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.en_US
dc.sourceASMEen_US
dc.titleDesign of an Ankle Rehabilitation Device Using Compliant Mechanismsen_US
dc.typeArticleen_US
dc.identifier.citationSung, Edward, Alexander H. Slocum, Raymond Ma, Jonathan F. Bean, and Martin L. Culpepper. “Design of an Ankle Rehabilitation Device Using Compliant Mechanisms.” Journal of Medical Devices 5, no. 1 (2011): 011001. © 2011 by ASMEen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineeringen_US
dc.contributor.mitauthorSung, Edward
dc.contributor.mitauthorSlocum Jr., Alexander H
dc.contributor.mitauthorMa, Raymond R
dc.relation.journalJournal of Medical Devicesen_US
dc.eprint.versionFinal published versionen_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dc.date.updated2019-01-02T16:44:49Z
dspace.orderedauthorsSung, Edward; Slocum, Alexander H.; Ma, Raymond; Bean, Jonathan F.; Culpepper, Martin L.en_US
dspace.embargo.termsNen_US
mit.licensePUBLISHER_POLICYen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record