The MIT Libraries is completing a major upgrade to DSpace@MIT. Starting May 5 2026, DSpace will remain functional, viewable, searchable, and downloadable, however, you will not be able to edit existing collections or add new material. We are aiming to have full functionality restored by May 18, 2026, but intermittent service interruptions may occur. Please email dspace-lib@mit.edu with any questions. Thank you for your patience as we implement this important upgrade.

Show simple item record

dc.contributor.authorMeskers, Arjan J. H.
dc.contributor.authorGupta, Rajiv
dc.contributor.authorWalsh, Conor James
dc.contributor.authorSlocum Jr., Alexander H
dc.date.accessioned2019-01-15T18:37:39Z
dc.date.available2019-01-15T18:37:39Z
dc.date.issued2012-10
dc.date.submitted2011-04
dc.identifier.issn1932-6181
dc.identifier.urihttp://hdl.handle.net/1721.1/120065
dc.description.abstractThis paper describes the design of a compact, lightweight CT-compatible, drill-press that is designed to be used in either a hand-held or stand-alone mode to assist with percutaneous bone based interventions. Previous medical drilling tools that have been developed have a metal structure and typically have one actuator for advancing the drill (feed) and another for rotating it (speed). After defining the device functional requirements and specifications, a deterministic design process was followed to generate several design concepts that were then evaluated based on their ability to satisfy the functional requirements. A final concept that uses a custom screw-spline to achieve helical motion of a shaft that is attached to a standard orthopedic drill was selected for prototyping. The design uses a single actuator to drive both the screw and spline nuts through two different gear ratios, resulting in a fixed ratio between the feed and speed. Apart from the motor which is placed away from the central drill axis, the device is largely made from plastic materials. A custom experimental setup was developed that enabled drilling into bone inside a CT scanner to be examined. Results showed that the device was successfully able to penetrate thick cortical bone and that its structure did not appreciably distort the medical images. Keywords: medical robotics, computed tomography, X-ray, drill, interventional radiology, boneen_US
dc.publisherASME Internationalen_US
dc.relation.isversionofhttp://dx.doi.org/10.1115/1.4007280en_US
dc.rightsArticle is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.en_US
dc.sourceASMEen_US
dc.titleCT-Compatible Medical Drilling Styleten_US
dc.typeArticleen_US
dc.identifier.citationWalsh, Conor J., Arjan J. H. Meskers, Alexander H. Slocum, and Rajiv Gupta. “CT-Compatible Medical Drilling Stylet.” Journal of Medical Devices 6, no. 4 (October 11, 2012): 041001. © 2012 American Society of Mechanical Engineeren_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineeringen_US
dc.contributor.mitauthorWalsh, Conor James
dc.contributor.mitauthorSlocum Jr., Alexander H
dc.relation.journalJournal of Medical Devicesen_US
dc.eprint.versionFinal published versionen_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dc.date.updated2019-01-02T16:34:26Z
dspace.orderedauthorsWalsh, Conor J.; Meskers, Arjan J. H.; Slocum, Alexander H.; Gupta, Rajiven_US
dspace.embargo.termsNen_US
mit.licensePUBLISHER_POLICYen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)