Show simple item record

dc.contributor.authorSingh, Vijay Raj
dc.contributor.authorRajapakse, Jagath C.
dc.contributor.authorYu, Hanry
dc.contributor.authorSo, Peter T. C.
dc.date.accessioned2019-02-19T18:19:11Z
dc.date.available2019-02-19T18:19:11Z
dc.date.issued2011-02
dc.identifier.urihttp://hdl.handle.net/1721.1/120485
dc.description.abstractThis paper presents an intensity normalization method for analysis of liver tissue images, acquired using the two-photon microscopy system at different stages of fibrosis. Image informatics methods require precise intensity segmentation for analysis of collagen, vessel and cellular structures. Intensities of the images recorded at different time intervals corresponding to the progression of fibrosis could vary spatially and temporally depending on the experimental conditions. These variations significantly affect the image segmentation process and thus the final image analysis, especially when automatic computer-based methods are used for diagnostic parameters quantification. We propose an adaptive intensity normalization method that facilitates spatial and temporal intensity variations of the images before the segmentation process. The images are first portioned into a tessellation of regions with relatively uniform background pixels intensities and then the normalization is performed to make sure the intensity range is unified throughout the whole set of image data. This approach is further extended for montage of images acquired from multianode photomultiplier tube based multifocal multiphoton microscope (MMM) system. The proposed approach significantly improves the automated analysis of images with varying intensities without any user intervention.en_US
dc.publisherSPIEen_US
dc.relation.isversionofhttp://dx.doi.org/10.1117/12.876246en_US
dc.rightsArticle is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.en_US
dc.sourceSPIEen_US
dc.titleIntensity normalization of two-photon microscopy images for liver fibrosis analysisen_US
dc.typeArticleen_US
dc.identifier.citationSingh, Vijay Raj, Jagath C. Rajapakse, Hanry Yu, and Peter T. C. So. “Intensity Normalization of Two-Photon Microscopy Images for Liver Fibrosis Analysis.” Proceedings Volume 7903, 22-27 January, 2011, San Francisco, California, USA, edited by Ammasi Periasamy, Karsten König, and Peter T. C. So, SPIE, 2011. © 2011 SPIE.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineeringen_US
dc.contributor.mitauthorYu, Hanry
dc.contributor.mitauthorSo, Peter T. C.
dc.relation.journalProceedings Volume 7903, Multiphoton Microscopy in the Biomedical Sciences XIen_US
dc.eprint.versionFinal published versionen_US
dc.type.urihttp://purl.org/eprint/type/ConferencePaperen_US
eprint.statushttp://purl.org/eprint/status/NonPeerRevieweden_US
dc.date.updated2019-01-03T17:29:08Z
dspace.orderedauthorsSingh, Vijay Raj; Rajapakse, Jagath C.; Yu, Hanry; So, Peter T. C.en_US
dspace.embargo.termsNen_US
dc.identifier.orcidhttps://orcid.org/0000-0002-0339-3685
dc.identifier.orcidhttps://orcid.org/0000-0003-4698-6488
mit.licensePUBLISHER_POLICYen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record