| dc.contributor.author | Strauss, T. | |
| dc.contributor.author | Conrad, Janet Marie | |
| dc.contributor.author | Jones, Benjamin James Poyner | |
| dc.contributor.author | Moss, Z. | |
| dc.contributor.author | Toups, Matthew | |
| dc.date.accessioned | 2019-03-14T17:26:50Z | |
| dc.date.available | 2019-03-14T17:26:50Z | |
| dc.date.issued | 2015-06 | |
| dc.date.submitted | 2015-02 | |
| dc.identifier.issn | 1748-0221 | |
| dc.identifier.uri | http://hdl.handle.net/1721.1/120958 | |
| dc.description.abstract | We report on the design and construction of a LED-based fiber calibration system for large liquid argon time projection detectors. This system was developed to calibrate the optical systems of the MicroBooNE experiment. As well as detailing the materials and installation procedure, we provide technical drawings and specifications so that the system may be easily replicated in future LArTPC detectors. | en_US |
| dc.description.sponsorship | National Science Foundation (U.S.) (Grant PHY-1205175) | en_US |
| dc.publisher | IOP Publishing | en_US |
| dc.relation.isversionof | http://dx.doi.org/10.1088/1748-0221/10/06/T06001 | en_US |
| dc.rights | Creative Commons Attribution-Noncommercial-Share Alike | en_US |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/4.0/ | en_US |
| dc.source | arXiv | en_US |
| dc.title | The photomultiplier tube calibration system of the MicroBooNE experiment | en_US |
| dc.type | Article | en_US |
| dc.identifier.citation | Conrad, J. et al. “The Photomultiplier Tube Calibration System of the MicroBooNE Experiment.” Journal of Instrumentation 10, 6 (June 2015): T06001–T06001 © 2015 IOP Publishing Ltd and Sissa Medialab | en_US |
| dc.contributor.department | Massachusetts Institute of Technology. Department of Physics | en_US |
| dc.contributor.department | Massachusetts Institute of Technology. Laboratory for Nuclear Science | en_US |
| dc.contributor.mitauthor | Conrad, Janet Marie | |
| dc.contributor.mitauthor | Jones, Benjamin James Poyner | |
| dc.contributor.mitauthor | Moss, Z. | |
| dc.contributor.mitauthor | Toups, Matthew | |
| dc.relation.journal | Journal of Instrumentation | en_US |
| dc.eprint.version | Original manuscript | en_US |
| dc.type.uri | http://purl.org/eprint/type/JournalArticle | en_US |
| eprint.status | http://purl.org/eprint/status/NonPeerReviewed | en_US |
| dc.date.updated | 2019-03-14T13:42:01Z | |
| dspace.orderedauthors | Conrad, J.; Jones, B.J.P.; Moss, Z.; Strauss, T.; Toups, M. | en_US |
| dspace.embargo.terms | N | en_US |
| dc.identifier.orcid | https://orcid.org/0000-0002-6393-0438 | |
| dc.identifier.orcid | https://orcid.org/0000-0001-6243-1453 | |
| mit.license | OPEN_ACCESS_POLICY | en_US |