Show simple item record

dc.contributor.authorAlver, Burak Han
dc.contributor.authorBauer, Gerry P
dc.contributor.authorBendavid, Joshua L.
dc.contributor.authorBusza, Wit
dc.contributor.authorButz, Erik M.
dc.contributor.authorCali, Ivan Amos
dc.contributor.authorChan, M.
dc.contributor.authorD'Enterria, David
dc.contributor.authorEveraerts, Pieter Bruno Bart
dc.contributor.authorGomez-Ceballos, Guillelmo
dc.contributor.authorHahn, Kristian Allan
dc.contributor.authorHarris, Philip Coleman
dc.contributor.authorJaditz, Stephen Hunter
dc.contributor.authorKim, Y.
dc.contributor.authorKlute, Markus
dc.contributor.authorLee, Youjin
dc.contributor.authorLi, W.
dc.contributor.authorLoizides, Constantinos
dc.contributor.authorMa, T.
dc.contributor.authorMiller, M.
dc.contributor.authorPaus, Christoph M. E.
dc.contributor.authorRoland, Christof E
dc.contributor.authorRoland, Gunther M
dc.contributor.authorRudolph, Matthew Scott
dc.contributor.authorStephans, George S. F.
dc.contributor.authorSumorok, Konstanty C
dc.contributor.authorSung, K.
dc.contributor.authorVaurynovich, Siarhei S.
dc.contributor.authorWenger, Edward Allen
dc.contributor.authorWyslouch, Boleslaw
dc.contributor.authorXie, Si
dc.contributor.authorYilmaz, Yetkin
dc.contributor.authorYoon, A. S.
dc.contributor.authorNahn, Steven
dc.date.accessioned2019-06-19T15:32:04Z
dc.date.available2019-06-19T15:32:04Z
dc.date.issued2010-03
dc.date.submitted2009-11
dc.identifier.issn1748-0221
dc.identifier.urihttps://hdl.handle.net/1721.1/121357
dc.description.abstractThe resolution and the linearity of time measurements made with the CMS electromagnetic calorimeter are studied with samples of data from test beam electrons, cosmic rays, and beam-produced muons. The resulting time resolution measured by lead tungstate crystals is better than 100 ps for energy deposits larger than 10 GeV. Crystal-to-crystal synchronization with a precision of 500 ps is performed using muons produced with the first LHC beams in 2008.en_US
dc.language.isoen
dc.publisherIOP Publishingen_US
dc.relation.isversionofhttp://dx.doi.org/10.1088/1748-0221/5/03/T03011en_US
dc.rightsCreative Commons Attribution-Noncommercial-Share Alikeen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/en_US
dc.sourcearXiven_US
dc.titleTime reconstruction and performance of the CMS electromagnetic calorimeteren_US
dc.typeArticleen_US
dc.identifier.citationChatrchyan, S. "Time reconstruction and performance of the CMS electromagnetic calorimeter." Journal of Instrumentation 5 (March 2010): T03011 © 2010 IOP Publishing Ltd and SISSAen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Physicsen_US
dc.contributor.departmentMassachusetts Institute of Technology. Laboratory for Nuclear Scienceen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Nuclear Science and Engineeringen_US
dc.relation.journalJournal of Instrumentationen_US
dc.eprint.versionOriginal manuscripten_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/NonPeerRevieweden_US
dc.date.updated2019-06-18T19:19:09Z
dspace.date.submission2019-06-18T19:19:10Z
mit.journal.volume5en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record