dc.contributor.author | Alver, Burak Han | |
dc.contributor.author | Bauer, Gerry P | |
dc.contributor.author | Bendavid, Joshua L. | |
dc.contributor.author | Busza, Wit | |
dc.contributor.author | Butz, Erik M. | |
dc.contributor.author | Cali, Ivan Amos | |
dc.contributor.author | Chan, M. | |
dc.contributor.author | D'Enterria, David | |
dc.contributor.author | Everaerts, Pieter Bruno Bart | |
dc.contributor.author | Gomez-Ceballos, Guillelmo | |
dc.contributor.author | Hahn, Kristian Allan | |
dc.contributor.author | Harris, Philip Coleman | |
dc.contributor.author | Jaditz, Stephen Hunter | |
dc.contributor.author | Kim, Y. | |
dc.contributor.author | Klute, Markus | |
dc.contributor.author | Lee, Y.-J. | |
dc.contributor.author | Li, W. | |
dc.contributor.author | Loizides, Constantinos | |
dc.contributor.author | Ma, T. | |
dc.contributor.author | Miller, M. | |
dc.contributor.author | Paus, Christoph M. E. | |
dc.contributor.author | Roland, Christof E | |
dc.contributor.author | Roland, Gunther M | |
dc.contributor.author | Rudolph, Matthew Scott | |
dc.contributor.author | Stephans, George S. F. | |
dc.contributor.author | Sumorok, Konstanty C | |
dc.contributor.author | Sung, K. | |
dc.contributor.author | Vaurynovich, Siarhei S. | |
dc.contributor.author | Wenger, Edward Allen | |
dc.contributor.author | Wyslouch, Boleslaw | |
dc.contributor.author | Xie, S. | |
dc.contributor.author | Yilmaz, Yetkin | |
dc.contributor.author | Yoon, A. S. | |
dc.contributor.author | CMS Collaboration | |
dc.contributor.author | Nahn, Steven | |
dc.date.accessioned | 2019-07-08T21:39:24Z | |
dc.date.available | 2019-07-08T21:39:24Z | |
dc.date.issued | 2010-03 | |
dc.date.submitted | 2009-11 | |
dc.identifier.issn | 1748-0221 | |
dc.identifier.uri | https://hdl.handle.net/1721.1/121526 | |
dc.description.abstract | In October and November 2008, the CMS collaboration conducted a programme of cosmic ray data taking, which has recorded about 270 million events. The Resistive Plate Chamber system, which is part of the CMS muon detection system, was successfully operated in the full barrel. More than 98% of the channels were operational during the exercise with typical detection efficiency of 90%. In this paper, the performance of the detector during these dedicated runs is reported. | en_US |
dc.language.iso | en | |
dc.relation.isversionof | http://dx.doi.org/10.1088/1748-0221/5/03/T03017 | en_US |
dc.rights | Creative Commons Attribution-Noncommercial-Share Alike | en_US |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/4.0/ | en_US |
dc.source | arXiv | en_US |
dc.title | Performance study of the CMS barrel resistive plate chambers with cosmic rays | en_US |
dc.type | Article | en_US |
dc.identifier.citation | Chatrchyan, S. et al. "Performance study of the CMS barrel resistive plate chambers with cosmic rays." Journal of Instrumentation 5 (March 2010): T03017 © 2010 IOP Publishing Ltd and SISSA | en_US |
dc.contributor.department | Massachusetts Institute of Technology. Department of Physics | en_US |
dc.contributor.department | Massachusetts Institute of Technology. Department of Nuclear Science and Engineering | en_US |
dc.contributor.department | Massachusetts Institute of Technology. Laboratory for Nuclear Science | en_US |
dc.relation.journal | Journal of Instrumentation | en_US |
dc.eprint.version | Original manuscript | en_US |
dc.type.uri | http://purl.org/eprint/type/JournalArticle | en_US |
eprint.status | http://purl.org/eprint/status/NonPeerReviewed | en_US |
dc.date.updated | 2019-06-19T14:06:11Z | |
dspace.date.submission | 2019-06-19T14:06:12Z | |
mit.journal.volume | 5 | en_US |