Alignment of the CMS silicon tracker during commissioning with cosmic rays

Author(s)
Alver, Burak Han; Bauer, Gerry P; Bendavid, Joshua L.; Busza, Wit; Butz, Erik M.; Cali, Ivan Amos; Chan, M.; D'Enterria, David; Everaerts, Pieter Bruno Bart; Gomez-Ceballos, Guillelmo; Hahn, K. A.; Harris, Philip Coleman; Jaditz, Stephen Hunter; Kim, Y.; Klute, Markus; Lee, Y.-J.; Li, W.; Loizides, Constantinos; Ma, T.; Miller, M.; Paus, Christoph M. E.; Roland, Christof E; Roland, Gunther M; Rudolph, Matthew Scott; Stephans, George S. F.; Sumorok, Konstanty C; Sung, K.; Vaurynovich, Siarhei S.; Wenger, Edward Allen; Wyslouch, Boleslaw; Xie, S.; Yilmaz, Yetkin; Yoon, A. S.; CMS Collaboration; Nahn, Steven; ... Show more Show less
Thumbnail
DownloadAccepted version (2.218Mb)
Terms of use
Creative Commons Attribution-Noncommercial-Share Alike http://creativecommons.org/licenses/by-nc-sa/4.0/
Metadata
Show full item record
Abstract
The CMS silicon tracker, consisting of 1440 silicon pixel and 15 148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions of the modules were determined with respect to cosmic ray trajectories to an average precision of 3-4 microns RMS in the barrel and 3-14 microns RMS in the endcap in the most sensitive coordinate. The results have been validated by several studies, including laser beam cross-checks, track fit self-consistency, track residuals in overlapping module regions, and track parameter resolution, and are compared with predictions obtained from simulation. Correlated systematic effects have been investigated. The track parameter resolutions obtained with this alignment are close to the design performance.
Date issued
2010-03
URI
https://hdl.handle.net/1721.1/121569
Department
Massachusetts Institute of Technology. Department of Physics; Massachusetts Institute of Technology. Laboratory for Nuclear Science; Massachusetts Institute of Technology. Department of Nuclear Science and Engineering
Journal
Journal of Instrumentation
Publisher
IOP Publishing
Citation
Chatrchyan, S. et al. "Alignment of the CMS silicon tracker during commissioning with cosmic rays." Journal of Instrumentation 5 (March 2010): T03009 © 2010 IOP Publishing Ltd and SISSA
Version: Author's final manuscript
ISSN
1748-0221

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.