Show simple item record

dc.contributor.authorApyan, Aram
dc.contributor.authorBauer, Gerry P
dc.contributor.authorBendavid, Joshua L.
dc.contributor.authorBusza, Wit
dc.contributor.authorButz, Erik M.
dc.contributor.authorCali, Ivan Amos
dc.contributor.authorChan, M.
dc.contributor.authorDutta, Valentina
dc.contributor.authorGomez-Ceballos, Guillelmo
dc.contributor.authorGoncharov, Maxim
dc.contributor.authorKim, Y.
dc.contributor.authorKlute, Markus
dc.contributor.authorKrajczar, Krisztian F.
dc.contributor.authorLevin, A.
dc.contributor.authorLuckey Jr, P David
dc.contributor.authorMa, T.
dc.contributor.authorPaus, Christoph M. E.
dc.contributor.authorRalph, Duncan Kelley
dc.contributor.authorRoland, Christof E
dc.contributor.authorRoland, Gunther M
dc.contributor.authorRudolph, Matthew Scott
dc.contributor.authorStephans, George S. F.
dc.contributor.authorSumorok, Konstanty C
dc.contributor.authorSung, K.
dc.contributor.authorVelicanu, Dragos Alexandru
dc.contributor.authorWenger, Edward Allen
dc.contributor.authorWolf, Roger
dc.contributor.authorWyslouch, Boleslaw
dc.contributor.authorYang, M.
dc.contributor.authorYilmaz, Y.
dc.contributor.authorYoon, A. S.
dc.contributor.authorZanetti, Marco
dc.contributor.authorWyslouch, Victoria
dc.contributor.authorNahn, Steven
dc.contributor.authorStoeckli, Fabian
dc.date.accessioned2019-07-15T21:13:02Z
dc.date.available2019-07-15T21:13:02Z
dc.date.issued2013-11
dc.date.submitted2013-06
dc.identifier.issn1748-0221
dc.identifier.urihttps://hdl.handle.net/1721.1/121715
dc.description.abstractThe performance of all subsystems of the CMS muon detector has been studied by using a sample of proton-proton collision data at √s = 7 TeV collected at the LHC in 2010 that corresponds to an integrated luminosity of approximately 40 pb⁻¹. The measured distributions of the major operational parameters of the drift tube (DT), cathode strip chamber (CSC), and resistive plate chamber (RPC) systems met the design specifications. The spatial resolution per chamber was 80–120 μm in the DTs, 40–150 μm in the CSCs, and 0.8–1.2 cm in the RPCs. The time resolution achievable was 3 ns or better per chamber for all 3 systems. The efficiency for reconstructing hits and track segments originating from muons traversing the muon chambers was in the range 95–98%. The CSC and DT systems provided muon track segments for the CMS trigger with over 96% efficiency, and identified the correct triggering bunch crossing in over 99.5% of such events. The measured performance is well reproduced by Monte Carlo simulation of the muon system down to the level of individual channel response. The results confirm the high efficiency of the muon system, the robustness of the design against hardware failures, and its effectiveness in the discrimination of backgrounds.en_US
dc.language.isoen
dc.publisherIOP Publishingen_US
dc.relation.isversionofhttp://dx.doi.org/10.1088/1748-0221/8/11/P11002en_US
dc.rightsCreative Commons Attribution 3.0 unported licenseen_US
dc.rights.urihttps://creativecommons.org/licenses/by/3.0/en_US
dc.sourceIOP Publishingen_US
dc.titleThe performance of the CMS muon detector in proton-proton collisions at √s = 7 TeV at the LHCen_US
dc.typeArticleen_US
dc.identifier.citationChatrchyan, S. et al. "The performance of the CMS muon detector in proton-proton collisions at √s = 7 TeV at the LHC." Journal of Instrumentation 8 (November 2013): P11002 © CERN 2013 for the benefit of the CMS collaborationen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Physicsen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Nuclear Science and Engineeringen_US
dc.contributor.departmentMassachusetts Institute of Technology. Laboratory for Nuclear Scienceen_US
dc.relation.journalJournal of Instrumentationen_US
dc.eprint.versionFinal published versionen_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dc.date.updated2019-05-21T12:45:44Z
dspace.date.submission2019-05-21T12:45:45Z
mit.journal.volume8en_US
mit.journal.issue2013en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record