MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Performance of the CMS drift-tube chamber local trigger with cosmic rays

Author(s)
Alver, Burak Han; Bauer, Gerry P; Bendavid, Joshua L.; Butz, Erik M.; Cali, Ivan Amos; Chan, M.; D'Enterria, David; Everaerts, Pieter Bruno Bart; Gomez-Ceballos, Guillelmo; Hahn, Kristian Allan; Harris, Philip Coleman; Jaditz, Stephen Hunter; Kim, Y.; Klute, Markus; Lee, Y.-J.; Li, W.; Loizides, Constantinos; Ma, T.; Miller, M.; Paus, Christoph M. E.; Roland, Christof E; Roland, Gunther M; Rudolph, Matthew Scott; Stephans, George S. F.; Sumorok, Konstanty C; Sung, K.; Vaurynovich, Siarhei S.; Wenger, Edward Allen; Wyslouch, Boleslaw; Xie, S.; Yilmaz, Yetkin; Yoon, A.S.; CMS Collaboration; Nahn, Steven; ... Show more Show less
Thumbnail
DownloadSubmitted version (1.271Mb)
Terms of use
Creative Commons Attribution-Noncommercial-Share Alike http://creativecommons.org/licenses/by-nc-sa/4.0/
Metadata
Show full item record
Abstract
The performance of the Local Trigger based on the drift-tube system of the CMS experiment has been studied using muons from cosmic ray events collected during the commissioning of the detector in 2008. The properties of the system are extensively tested and compared with the simulation. The effect of the random arrival time of the cosmic rays on the trigger performance is reported, and the results are compared with the design expectations for proton-proton collisions and with previous measurements obtained with muon beams.
Date issued
2010-03
URI
https://hdl.handle.net/1721.1/121952
Department
Massachusetts Institute of Technology. Department of Physics; Massachusetts Institute of Technology. Laboratory for Nuclear Science; Massachusetts Institute of Technology. Department of Nuclear Science and Engineering
Journal
Journal of Instrumentation
Publisher
IOP Publishing
Citation
Chatrchyan, S. et al. "Performance of the CMS drift-tube chamber local trigger with cosmic rays." Journal of Instrumentation 5 (March 2010): T03003 © 2010 IOP Publishing and SISSA
Version: Original manuscript
ISSN
1748-0221

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.