Performance of the CMS cathode strip chambers with cosmic rays

Author(s)
Alver, Burak Han; Bauer, Gerry P; Bendavid, Joshua L.; Busza, Wit; Butz, Erik M.; Cali, Ivan Amos; Chan, M.; D'Enterria, David; Everaerts, Pieter Bruno Bart; Gomez-Ceballos, Guillelmo; Hahn, Kristian Allan; Harris, Philip Coleman; Jaditz, Stephen Hunter; Kim, Y.; Klute, Markus; Lee, Y.-J.; Li, W.; Loizides, Constantinos; Ma, T.; Miller, M.; Paus, Christoph M. E.; Roland, Christof E; Roland, Gunther M; Rudolph, Matthew Scott; Stephans, George S. F.; Sumorok, Konstanty C; Sung, K.; Vaurynovich, Siarhei S.; Wenger, Edward Allen; Wyslouch, Boleslaw; Xie, S.; Yilmaz, Yetkin; Yoon, A. S.; Nahn, Steven; ... Show more Show less
Thumbnail
DownloadSubmitted version (1.477Mb)
Terms of use
Creative Commons Attribution-Noncommercial-Share Alike http://creativecommons.org/licenses/by-nc-sa/4.0/
Metadata
Show full item record
Abstract
The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47μm to 243μm. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns.
Date issued
2010-03
URI
https://hdl.handle.net/1721.1/121955
Department
Massachusetts Institute of Technology. Department of Physics; Massachusetts Institute of Technology. Department of Nuclear Science and Engineering; Massachusetts Institute of Technology. Laboratory for Nuclear Science
Journal
Journal of Instrumentation
Publisher
IOP Publishing
Citation
Chatrchyan, S. et al. "Performance of the CMS cathode strip chambers with cosmic rays." Journal of Instrumentation 5 (March 2010): T03018 © 2010 IOP Publishing Ltd and SISSA
Version: Original manuscript
ISSN
1748-0221

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.