Multimodal photoplethysmography-based approaches for improved detection of hypertension

Author(s)
Fletcher, Richard R
Thumbnail
Downloadjcm-09-01203.pdf (3.453Mb)
Publisher with Creative Commons License

Publisher with Creative Commons License

Creative Commons Attribution

Terms of use
Creative Commons Attribution https://creativecommons.org/licenses/by/4.0/
Metadata
Show full item record
Abstract
Elevated blood pressure (BP) is a major cause of death, yet hypertension commonly goes undetected. Owing to its nature, it is typically asymptomatic until later in its progression when the vessel or organ structure has already been compromised. Therefore, noninvasive and continuous BP measurement methods are needed to ensure appropriate diagnosis and early management before hypertension leads to irreversible complications. Photoplethysmography (PPG) is a noninvasive technology with waveform morphologies similar to that of arterial BP waveforms, therefore attracting interest regarding its usability in BP estimation. In recent years, wearable devices incorporating PPG sensors have been proposed to improve the early diagnosis and management of hypertension. Additionally, the need for improved accuracy and convenience has led to the development of devices that incorporate multiple different biosignals with PPG. Through the addition of modalities such as an electrocardiogram, a final measure of the pulse wave velocity is derived, which has been proved to be inversely correlated to BP and to yield accurate estimations. This paper reviews and summarizes recent studies within the period 2010-2019 that combined PPG with other biosignals and offers perspectives on the strengths and weaknesses of current developments to guide future advancements in BP measurement. Our literature review reveals promising measurement accuracies and we comment on the effective combinations of modalities and success of this technology. ©2020 Keywords: photoplethysmogram; PPG signal; pulse oximetry; hypertension assessment; hypertension diagnosis; blood pressure measurement; wearable technology; wearable devices; digital health; digital medicine; pulse arrival time; biomedical engineering
Date issued
2020-04
URI
https://hdl.handle.net/1721.1/125307
Department
Massachusetts Institute of Technology. Office of Experiential Learning
Journal
Journal of Clinical Medicine
Publisher
Multidisciplinary Digital Publishing Institute
Citation
Welykholowa, Kaylie, et al., "Multimodal photoplethysmography-based approaches for improved detection of hypertension." Journal of Clinical Medicine 9, 4 (Apr. 2020): no. 1203 doi 10.3390/jcm9041203 ©2020 Author(s)
Version: Final published version
ISSN
2077-0383

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.