Automated Segmentation of Bioresorbable Vascular Scaffold Struts in Intracoronary Optical Coherence Tomography Images

Author(s)
Athanasiou, Lambros S.; Rikhtegar Nezami, Farhad; de la Torre Hernández, Jose; Edelman, Elazer R
Thumbnail
DownloadAccepted version (1.337Mb)
Terms of use
Creative Commons Attribution-Noncommercial-Share Alike http://creativecommons.org/licenses/by-nc-sa/4.0/
Metadata
Show full item record
Abstract
Bioresorbable vascular scaffolds (BVS), the next step in the continuum of minimally invasive vascular interventions present new opportunities for patients and clinicians but challenges as well. As they are comprised of polymeric materials standard imaging is challenging. This is especially problematic as modalities like optical coherence tomography (OCT) become more prevalent in cardiology. OCT, a light-based intracoronary imaging technique, provides cross-sectional images of plaque and luminal morphology. Until recently segmentation of OCT images for BVS struts was performed manually by experts. However, this process is time consuming and not tractable for large amounts of patient data. Several automated methods exist to segment metallic stents, which do not apply to the newer BVS. Given this current limitation coupled with the emerging popularity of the BVS technology, it is crucial to develop an automated methodology to segment BVS struts in OCT images. The objective of this paper is to develop a novel BVS strut detection method in intracoronary OCT images. First, we pre-process the image to remove imaging artifacts. Then, we use a K-means clustering algorithm to automatically segment the image. Finally, we isolate the stent struts from the rest of the image. The accuracy of the proposed method was evaluated using expert estimations on 658 annotated images acquired from 7 patients at the time of coronary arterial interventions. Our proposed methodology has a positive predictive value of 0.93, a Pearson Correlation coefficient of 0.94, and a F1 score of 0.92. The proposed methodology allows for rapid, accurate, and fully automated segmentation of BVS struts in OCT images.
Date issued
2017-10
URI
https://hdl.handle.net/1721.1/126560
Department
Institute for Medical Engineering and Science
Journal
2017 IEEE 17th International Conference on Bioinformatics and Bioengineering (BIBE)
Publisher
Institute of Electrical and Electronics Engineers (IEEE)
Citation
Amrute, Junedh M. et al. “Automated Segmentation of Bioresorbable Vascular Scaffold Struts in Intracoronary Optical Coherence Tomography Images.” Paper presented at the 2017 IEEE 17th International Conference on Bioinformatics and Bioengineering (BIBE), Washington, D.C., 23-25 Oct. 2017, IEEE © 2017 The Author(s)
Version: Author's final manuscript
ISSN
2471-7819

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries homeMIT Libraries logo

Find us on

Twitter Facebook Instagram YouTube RSS

MIT Libraries navigation

SearchHours & locationsBorrow & requestResearch supportAbout us
PrivacyPermissionsAccessibility
MIT
Massachusetts Institute of Technology
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.