dc.description.abstractThe phase stability of a 140-GHz, 1-kW pulsed gyro-amplifier system and the phase dependence on the cathode voltage were experimentally measured. To optimize the measurement precision, the amplifier was operated at 47 kV and 1 A, where the output power was ∼30 W. The phase was determined to be stable both pulse-to-pulse and during each pulse, so far as the cathode voltage and electron beam current are constant. The phase variation with voltage was measured and found to be 130 ± 30°/kV, in excellent agreement with simulations. The electron gun used in this device is non-adiabatic, resulting in a steep slope of the beam pitch factor with respect to cathode voltage. This was discovered to be the dominant factor in the phase dependence on voltage. The use of an adiabatic electron gun is predicted to yield a significantly smaller phase sensitivity to voltage, and thus a more phase-stable performance. To our knowledge, these are the first phase measurements reported for a gyro-amplifier operating at a frequency above W-band.en_US
dc.description.sponsorshipNIH and NIBIB (Grants R01-EB004866 and R01-EB001965)en_US
dc.description.sponsorshipDOE (Grant DE-FC02-93ER54186)en_US
dc.publisherSpringer Science and Business Media LLCen_US
dc.relation.isversionofhttp://dx.doi.org/10.1007/s10762-020-00751-wen_US
dc.rightsArticle is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.en_US
dc.sourceTemkinen_US
dc.titlePhase Measurements of a 140-GHz Confocal Gyro-Amplifieren_US
dc.typeArticleen_US
dc.identifier.citationRosenzweig, Guy et al. "Phase Measurements of a 140-GHz Confocal Gyro-Amplifier." Journal of Infrared, Millimeter, and Terahertz Waves 41 (October 2020): doi.org/10.1007/s10762-020-00751-w © 2020 Springer Science Business Media, LLC, part of Springer Natureen_US
dc.contributor.departmentMassachusetts Institute of Technology. Plasma Science and Fusion Centeren_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Physicsen_US
dc.relation.journalJournal of Infrared, Millimeter, and Terahertz Wavesen_US
dc.eprint.versionAuthor's final manuscripten_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dspace.date.submission2020-10-28T13:59:51Z
mit.journal.volume41en_US
mit.licensePUBLISHER_POLICY
mit.metadata.statusComplete


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record