Application of Transmural Flow Across In Vitro Microvasculature Enables Direct Sampling of Interstitial Therapeutic Molecule Distribution
Author(s)
Offeddu, Giovanni; Possenti, Luca; Loessberg‐Zahl, Joshua T; Zunino, Paolo; Roberts, John; Han, Xiaogang; Hickman, Dean; Knutson, Charles G; Kamm, Roger Dale; ... Show more Show less
DownloadAccepted version (1.547Mb)
Open Access Policy
Open Access Policy
Creative Commons Attribution-Noncommercial-Share Alike
Terms of use
Metadata
Show full item recordAbstract
In vitro prediction of physiologically relevant transport of therapeutic molecules across the microcirculation represents an intriguing opportunity to predict efficacy in human populations. On-chip microvascular networks (MVNs) show physiologically relevant values of molecular permeability, yet like most systems, they lack an important contribution to transport: the ever-present fluid convection through the endothelium. Quantification of transport through the MVNs by current methods also requires confocal imaging and advanced analytical techniques, which can be a bottleneck in industry and academic laboratories. Here, it is shown that by recapitulating physiological transmural flow across the MVNs, the concentration of small and large molecule therapeutics can be directly sampled in the interstitial fluid and analyzed using standard analytical techniques. The magnitudes of transport measured in MVNs reveal trends with molecular size and type (protein versus nonprotein) that are expected in vivo, supporting the use of the MVNs platform as an in vitro tool to predict distribution of therapeutics in vivo.
Date issued
2019-09Department
Massachusetts Institute of Technology. Department of Biological EngineeringJournal
Small
Publisher
Wiley
Citation
Offeddu, Giovanni et al. "Application of Transmural Flow Across In Vitro Microvasculature Enables Direct Sampling of Interstitial Therapeutic Molecule Distribution." Small 15, 46 (November 2019): 1902393 © 2019 Wiley
Version: Author's final manuscript