Show simple item record

dc.contributor.authorWang, Nan
dc.contributor.authorKanhere, Elgar
dc.contributor.authorKottapalli, Ajay Giri Prakash
dc.contributor.authorMiao, Jianmin
dc.contributor.authorTriantafyllou, Michael S
dc.date.accessioned2020-11-25T17:36:30Z
dc.date.available2020-11-25T17:36:30Z
dc.date.issued2017-05
dc.date.submitted2017-01
dc.identifier.issn0026-3672
dc.identifier.issn1436-5073
dc.identifier.urihttps://hdl.handle.net/1721.1/128657
dc.description.abstractThe authors describe a liquid crystal polymer (LCP) based bismuth (Bi) film electrode that can be directly deployed for in-situ determination of zinc(II) ions. The use of an LCP warrants improved operational reliability, high durability, and flexibility of the sensor, allowing it to be mounted on any flat or shaped surface. Square wave anodic stripping voltammetry shows the sensor to be able to detect Zn(II) (−1.64 V vs. thin-film Ag/AgCl reference electrode) in concentrations as low as 1.22 nM at a deposition time of 180 s. Other figures of merit include (a) an analytical sensitivity of 1.55 nA∙nM−1∙mm−2, (b) a linear detection range extending from 4.59 to 1071 nM, (c) a repeatability with a relative standard deviation of 3.35% (for n = 10), (d) a reproducibility with a relative standard deviation of 1.64% (for n = 6). Real-time applicability of the sensor for in-situ detection was demonstrated by determination of Zn(II) in seawater. In an extension of the method, a flexible sensor array consisting of four LCP-based sensors was attached to the hull of an autonomous kayak, which was remotely operated. The response of the sensor array indicated a clear trace of Zn(II) concentrations in seawater. This was confirmed by ICP-MS analysis. The results suggest the potential usage of the flexible LCP electrochemical sensor for in-situ monitoring.en_US
dc.language.isoen
dc.publisherSpringer Science and Business Media LLCen_US
dc.relation.isversionofhttp://dx.doi.org/10.1007/s00604-017-2280-6en_US
dc.rightsCreative Commons Attribution-Noncommercial-Share Alikeen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/en_US
dc.sourceOther repositoryen_US
dc.titleFlexible liquid crystal polymer-based electrochemical sensor for in-situ detection of zinc(II) in seawateren_US
dc.typeArticleen_US
dc.identifier.citationWang, Nan. "Flexible liquid crystal polymer-based electrochemical sensor for in-situ detection of zinc(II) in seawater." Microchimica Acta 184, 8 (May 2017): 3007–3015 © 2017 Springer-Verlagen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineeringen_US
dc.relation.journalMicrochimica Actaen_US
dc.eprint.versionAuthor's final manuscripten_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dc.date.updated2020-08-10T16:25:20Z
dspace.date.submission2020-08-10T16:25:22Z
mit.journal.volume184en_US
mit.journal.issue8en_US
mit.licenseOPEN_ACCESS_POLICY
mit.metadata.statusComplete


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record