Show simple item record

dc.contributor.authorFrydman, Galit H.
dc.contributor.authorEllett, Felix
dc.contributor.authorVan Cott, Elizabeth M.
dc.contributor.authorHayden, Douglas
dc.contributor.authorMajmudar, Maulik
dc.contributor.authorVanderburg, Charles R.
dc.contributor.authorDalzell, Haley
dc.contributor.authorPadmanabhan, Divya L.
dc.contributor.authorDavis, Nick
dc.contributor.authorJorgensen, Julianne
dc.contributor.authorToner, Mehmet
dc.contributor.authorFox, James G
dc.contributor.authorTompkins, Ronald G.
dc.date.accessioned2020-11-30T15:38:44Z
dc.date.available2020-11-30T15:38:44Z
dc.date.issued2019-08
dc.identifier.issn2639-8028
dc.identifier.urihttps://hdl.handle.net/1721.1/128674
dc.description.abstractDetermining whether a patient has taken a direct oral anticoagulant (DOAC) is critical during the periprocedural and preoperative period in the emergency department. However, the inaccessibility of complete medical records, along with the generally inconsistent sensitivity of conventional coagulation tests to these drugs, complicates clinical decision making and puts patients at risk of uncontrollable bleeding. In this study, we evaluate the utility of inhibitor-II-X (i-II-X), a novel, microfluidics-based diagnostic assay for the detection and identification of Factor Xa inhibitors (FXa-Is) in an acute care setting. Design: First-in-human, 91-patient, single-center retrospective pilot study. Setting: Emergency room. Patients: Adult patients admitted into the emergency department, which received any clinician-ordered coagulation test requiring a 3.2% buffered sodium citrate blood collection tube. Interventions: None. Measurements and Main Results: Plasma samples from patients admitted to the emergency department were screened for the use of FXa-Is, including apixaban and rivaroxaban, within the past 24 hours using our new i-II-X microfluidic test. i-II-X results were then compared with results from conventional coagulation tests, including prothrombin time (PT) and international normalized ratio (INR), which were ordered by treating clinicians, and an anti-Xa assay for rivaroxaban. The i-II-X test detected DOACs in samples collected from the emergency department with 95.20% sensitivity and 100.00% specificity. Unlike PT and INR, i-II-X reliably identified patients who had prolonged clotting times secondary to the presence of a FXa-I. Conclusions: The i-II-X test overcomes the limitations of currently available coagulation tests and could be a useful tool by which to routinely screen patients for DOACs in emergency and critical care settings. Our new diagnostic approach is particularly relevant in clinical situations where medical records may be unavailable, or where precautions need to be taken prior to invasive interventions, such as specific reversal agent administration.en_US
dc.language.isoen
dc.publisherOvid Technologies (Wolters Kluwer Health)en_US
dc.relation.isversionofhttp://dx.doi.org/10.1097/cce.0000000000000024en_US
dc.rightsCreative Commons Attribution-NonCommercial-NoDerivs Licenseen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/en_US
dc.sourceWolters Kluweren_US
dc.titleA New Test for the Detection of Direct Oral Anticoagulants (Rivaroxaban and Apixaban) in the Emergency Room Settingen_US
dc.typeArticleen_US
dc.identifier.citationFrydman, Galit H. et al. "A New Test for the Detection of Direct Oral Anticoagulants (Rivaroxaban and Apixaban) in the Emergency Room Setting." Critical Care Explorations 1, 8 (August 2019): e0024. © 2019 The Authorsen_US
dc.contributor.departmentMassachusetts Institute of Technology. Division of Comparative Medicineen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Biological Engineeringen_US
dc.relation.journalCritical Care Explorationsen_US
dc.eprint.versionFinal published versionen_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dc.date.updated2020-05-04T19:45:20Z
dspace.date.submission2020-05-04T19:45:22Z
mit.journal.volume1en_US
mit.journal.issue8en_US
mit.licensePUBLISHER_CC
mit.metadata.statusComplete


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record