High-Speed, Ultrahigh-Resolution Spectral-Domain OCT with Extended Imaging Range Using Reference Arm Length Matching

Author(s)
Lee, ByungKun; Chen, Siyu; Moult, Eric Michael; Yu, Yue; Fujimoto, James G
Thumbnail
DownloadPublished version (8.591Mb)
Publisher with Creative Commons License

Publisher with Creative Commons License

Creative Commons Attribution

Terms of use
Creative Commons Attribution-NonCommercial-NoDerivs License http://creativecommons.org/licenses/by-nc-nd/4.0/
Metadata
Show full item record
Abstract
Purpose: To develop high-speed, extended-range, ultrahigh-resolution spectraldomain optical coherence tomography (UHR SD-OCT) and demonstrate scan protocols for clinical retinal imaging. Methods: A UHR SD-OCT operating at 840-nm with 150-nm bandwidths was developed. The axial imaging range was extended by dynamically matching reference arm length to the retinal contour during acquisition. Two scan protocols were demonstrated for imaging healthy participants and patients with dry age-related macular degeneration. A high-definition raster protocol with intra–B-scan reference arm length matching (ReALM) was used for high-quality cross-sectional imaging. A cube volume scan using horizontal and vertical rasters with inter–B-scan ReALM and software motion correction was used for en face and cross-sectional imaging. Linear OCT signal display enhanced visualization of outer retinal features. Results: UHR SD-OCT was demonstrated at 128-and 250-kHz A-scan rates with 2.7 μm axial resolution and a 1.2-mm, 6-dB imaging range in the eye. Dynamic ReALM was used to maintain the retina within the 6-dB imaging range over wider fields of view. Outer retinal features, including the rod and cone interdigitation zones, retinal pigment epithelium, and Bruch’s membrane were visualized and alterations observed in agerelated macular degeneration eyes. Conclusions: Technological advances and dynamic ReALM improve the imaging performance and clinical usability of UHR SD-OCT. Translational Relevance: These advances should simplify clinical imaging workflow, reduce imaging session times, and improve yield of high quality images. Improved visualization of photoreceptors, retinal pigment epithelium, and Bruch’s membrane may facilitate diagnosis and monitoring of age-related macular degeneration and other retinal diseases.
Date issued
2020-06
URI
https://hdl.handle.net/1721.1/129541
Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science; Massachusetts Institute of Technology. Research Laboratory of Electronics
Journal
Translational Vision Science and Technology
Publisher
Association for Research in Vision and Ophthalmology (ARVO)
Citation
Lee, ByungKun et al. “High-Speed, Ultrahigh-Resolution Spectral-Domain OCT with Extended Imaging Range Using Reference Arm Length Matching.” Translational Vision Science and Technology, 9, 7 (June 2020): 12 © 2020 The Author(s)
Version: Final published version
ISSN
2164-2591

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.