Show simple item record

dc.contributor.authorAthanasiou, Lambros S
dc.contributor.authorNezami, Farhad R
dc.contributor.authorEdelman, Elazer R
dc.date.accessioned2021-09-20T17:16:51Z
dc.date.available2021-09-20T17:16:51Z
dc.date.issued2019-06-17
dc.identifier.urihttps://hdl.handle.net/1721.1/131383
dc.description.abstractAbstract Aortic dissections are challenging for it remains perplexing to determine when surgical, endovascular, or medical therapies are optimal. We studied the effect of the multilayer flow modulator (MFM) device in patients with different forms of type-B aortic dissections. CT scans were performed pre-, immediately post-MFM implantation, and multiple times within a 24-month follow-up. Three-dimensional reconstructions were created from these scans and the multilayer or single-layer mesh device placed virtually into the true lumen. We observed that MFM device can sufficiently restore flow perfusion, reduce the false lumen, eliminate local flow recirculation, and reduce wall shear stress distribution globally. Single-layer devices can reduce false lumen dimensions; however, they generate local disturbance and recirculation zones in selected areas at specific time points. Moreover, in polar extremes of dissection, the MFM device restored flow to vital organs perfusing vessels independent of effects on luminal patency. Management of aortic dissections should focus on modulation of blood flow, suppression of local recirculation, and restoration of vital organ perfusion rather than primarily restoring vascular lumen morphology. While the latter restores the geometry of the true lumen, only the former restores homeostasis. Graphical abstracten_US
dc.publisherSpringer Berlin Heidelbergen_US
dc.relation.isversionofhttps://doi.org/10.1007/s11517-019-01997-wen_US
dc.rightsCreative Commons Attribution-Noncommercial-Share Alikeen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/en_US
dc.sourceSpringer Berlin Heidelbergen_US
dc.titleHemodynamic consequences of a multilayer flow modulator in aortic dissectionen_US
dc.typeArticleen_US
dc.contributor.departmentMassachusetts Institute of Technology. Institute for Medical Engineering & Science
dc.eprint.versionAuthor's final manuscripten_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dc.date.updated2020-09-24T21:04:42Z
dc.language.rfc3066en
dc.rights.holderInternational Federation for Medical and Biological Engineering
dspace.embargo.termsY
dspace.date.submission2020-09-24T21:04:42Z
mit.licenseOPEN_ACCESS_POLICY
mit.metadata.statusAuthority Work and Publication Information Needed


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record