Show simple item record

dc.contributor.authorSerpa Neto, Ary
dc.contributor.authorDeliberato, Rodrigo O
dc.contributor.authorJohnson, Alistair E W
dc.contributor.authorBos, Lieuwe D
dc.contributor.authorAmorim, Pedro
dc.contributor.authorPereira, Silvio M
dc.contributor.authorCazati, Denise C
dc.contributor.authorCordioli, Ricardo L
dc.contributor.authorCorrea, Thiago D
dc.contributor.authorPollard, Tom J
dc.contributor.authorSchettino, Guilherme P P
dc.contributor.authorTimenetsky, Karina T
dc.contributor.authorCeli, Leo A
dc.contributor.authorPelosi, Paolo
dc.date.accessioned2021-09-20T17:17:02Z
dc.date.available2021-09-20T17:17:02Z
dc.date.issued2018-10-05
dc.identifier.urihttps://hdl.handle.net/1721.1/131428
dc.description.abstractAbstract Purpose Mechanical power (MP) may unify variables known to be related to development of ventilator-induced lung injury. The aim of this study is to examine the association between MP and mortality in critically ill patients receiving invasive ventilation for at least 48 h. Methods This is an analysis of data stored in the databases of the MIMIC–III and eICU. Critically ill patients receiving invasive ventilation for at least 48 h were included. The exposure of interest was MP. The primary outcome was in-hospital mortality. Results Data from 8207 patients were analyzed. Median MP during the second 24 h was 21.4 (16.2–28.1) J/min in MIMIC-III and 16.0 (11.7–22.1) J/min in eICU. MP was independently associated with in-hospital mortality [odds ratio per 5 J/min increase (OR) 1.06 (95% confidence interval (CI) 1.01–1.11); p = 0.021 in MIMIC-III, and 1.10 (1.02–1.18); p = 0.010 in eICU]. MP was also associated with ICU mortality, 30-day mortality, and with ventilator-free days, ICU and hospital length of stay. Even at low tidal volume, high MP was associated with in-hospital mortality [OR 1.70 (1.32–2.18); p < 0.001] and other secondary outcomes. Finally, there is a consistent increase in the risk of death with MP higher than 17.0 J/min. Conclusion High MP of ventilation is independently associated with higher in-hospital mortality and several other outcomes in ICU patients receiving invasive ventilation for at least 48 h.en_US
dc.publisherSpringer Berlin Heidelbergen_US
dc.relation.isversionofhttps://doi.org/10.1007/s00134-018-5375-6en_US
dc.rightsArticle is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.en_US
dc.sourceSpringer Berlin Heidelbergen_US
dc.titleMechanical power of ventilation is associated with mortality in critically ill patients: an analysis of patients in two observational cohortsen_US
dc.typeArticleen_US
dc.contributor.departmentMassachusetts Institute of Technology. Institute for Medical Engineering & Science
dc.contributor.departmentHarvard--MIT Program in Health Sciences and Technology. Laboratory for Computational Physiology
dc.eprint.versionAuthor's final manuscripten_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dc.date.updated2020-09-24T20:45:14Z
dc.language.rfc3066en
dc.rights.holderSpringer-Verlag GmbH Germany, part of Springer Nature and ESICM
dspace.embargo.termsY
dspace.date.submission2020-09-24T20:45:14Z
mit.licensePUBLISHER_POLICY
mit.metadata.statusAuthority Work and Publication Information Needed


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record