MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Dual Carbon Dioxide Capture to Achieve Highly Efficient Ultra-Low Blood Flow Extracorporeal Carbon Dioxide Removal

Author(s)
Chang, Brian Y; Keller, Steven P
Thumbnail
Download10439_2020_2477_ReferencePDF.pdf (783.2Kb)
Publisher Policy

Publisher Policy

Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.

Terms of use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Metadata
Show full item record
Abstract
Abstract Extracorporeal CO2 removal is a highly promising support therapy for patients with hypercapnic respiratory failure but whose clinical implementation and patient benefit is hampered by high cost and highly specialized expertise required for safe use. Current approaches target removal of the gaseous CO2 dissolved in blood which limits their ease of clinical use as high blood flow rates are required to achieve physiologically significant CO2 clearance. Here, a novel hybrid approach in which a zero-bicarbonate dialysis is used to target removal of bicarbonate ion coupled to a gas exchange device to clear dissolved CO2, achieves highly efficiently total CO2 capture while maintaining systemic acid–base balance. In a porcine model of acute hypercapnic respiratory failure, a CO2-reduction of 61.4 ± 14.4 mL/min was achieved at a blood flow rate of 248 mL/min using pediatric-scale priming volumes. The dialyzer accounted for 81% of total CO2 capture with an efficiency of 33% with a minimal pH change across the entire circuit. This study demonstrates the feasibility of a novel hybrid CO2 capture approach capable of achieving physiologically significant CO2 removal at ultralow blood flow rates with low priming volumes while leveraging widely available dialysis platforms to enable clinical adoption.
Date issued
2020-02-18
URI
https://hdl.handle.net/1721.1/131548
Department
Massachusetts Institute of Technology. Institute for Medical Engineering & Science
Publisher
Springer International Publishing

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.