Show simple item record

dc.contributor.authorNikolaev, Evgeny
dc.contributor.authorSudakov, Mikhail
dc.contributor.authorVladimirov, Gleb
dc.contributor.authorVelásquez-García, Luis F
dc.contributor.authorBorisovets, Petr
dc.contributor.authorFursova, Anastasia
dc.date.accessioned2021-09-20T17:30:57Z
dc.date.available2021-09-20T17:30:57Z
dc.date.issued2018-08-01
dc.identifier.urihttps://hdl.handle.net/1721.1/131923
dc.description.abstractAbstract Based on the analysis of the results of the study of various designs of multi-electrode harmonized Kingdon traps, we propose a new type of trap with two merged internal electrodes that has the ability to capture and accumulate ions formed inside. We also investigated the influence of inaccuracies in the manufacture of the electrodes on the field inside such trap. The four-electrode trap, which actually degenerates into a two-electrode device with traces of two other electrodes present at the ends of the internal electrodes (their splitting) has been found as the less sensitive to inaccuracies caused by manufacturing and cutting the ends of trap electrodes. We show that a mass spectrometer with a relatively high resolving power can be created on the basis of such a trap. The creation of the traps requires the manufacture of complex electrodes with demanded accuracy of their surfaces. This becomes possible with the advent of 3D printers. Graphical Abstract Multi electrode harmonize Kingdon trap with fused elctrode paresen_US
dc.publisherSpringer USen_US
dc.relation.isversionofhttps://doi.org/10.1007/s13361-018-2032-9en_US
dc.rightsArticle is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.en_US
dc.sourceSpringer USen_US
dc.titleMulti-electrode Harmonized Kingdon Trapsen_US
dc.typeArticleen_US
dc.contributor.departmentMassachusetts Institute of Technology. Microsystems Technology Laboratories
dc.eprint.versionAuthor's final manuscripten_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dc.date.updated2020-09-24T21:48:03Z
dc.language.rfc3066en
dc.rights.holderAmerican Society for Mass Spectrometry
dspace.embargo.termsY
dspace.date.submission2020-09-24T21:48:03Z
mit.licensePUBLISHER_POLICY
mit.metadata.statusAuthority Work and Publication Information Needed