dc.contributor.authorBarandov, Ali
dc.contributor.authorBartelle, Benjamin B
dc.contributor.authorWilliamson, Catherine G
dc.contributor.authorLoucks, Emily S
dc.contributor.authorLippard, Stephen J
dc.contributor.authorJasanoff, Alan
dc.date.accessioned2021-10-27T20:11:00Z
dc.date.available2021-10-27T20:11:00Z
dc.date.issued2019
dc.identifier.urihttps://hdl.handle.net/1721.1/135156
dc.description.abstract© 2019, The Author(s). Calcium ions are essential to signal transduction in virtually all cells, where they coordinate processes ranging from embryogenesis to neural function. Although optical probes for intracellular calcium imaging have been available for decades, the development of probes for noninvasive detection of intracellular calcium signaling in deep tissue and intact organisms remains a challenge. To address this problem, we synthesized a manganese-based paramagnetic contrast agent, ManICS1-AM, designed to permeate cells, undergo esterase cleavage, and allow intracellular calcium levels to be monitored by magnetic resonance imaging (MRI). Cells loaded with ManICS1-AM show changes in MRI contrast when stimulated with pharmacological agents or optogenetic tools; responses directly parallel the signals obtained using fluorescent calcium indicators. Introduction of ManICS1-AM into rodent brains furthermore permits MRI-based measurement of neural activation in optically inaccessible brain regions. These results thus validate ManICS1-AM as a calcium sensor compatible with the extensive penetration depth and field of view afforded by MRI.
dc.language.isoen
dc.publisherSpringer Science and Business Media LLC
dc.relation.isversionof10.1038/S41467-019-08558-7
dc.rightsCreative Commons Attribution 4.0 International license
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.sourceNature
dc.titleSensing intracellular calcium ions using a manganese-based MRI contrast agent
dc.typeArticle
dc.relation.journalNature Communications
dc.eprint.versionFinal published version
dc.type.urihttp://purl.org/eprint/type/JournalArticle
eprint.statushttp://purl.org/eprint/status/PeerReviewed
dc.date.updated2019-07-18T14:53:24Z
dspace.orderedauthorsBarandov, A; Bartelle, BB; Williamson, CG; Loucks, ES; Lippard, SJ; Jasanoff, A
dspace.date.submission2019-07-18T14:53:25Z
mit.journal.volume10
mit.journal.issue1
mit.metadata.statusAuthority Work and Publication Information Needed