MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Passive Prosthetic Foot Shape and Size Optimization Using Lower Leg Trajectory Error

Author(s)
Olesnavage, Kathryn M; Prost, Victor; Johnson, William Brett; Winter, Amos G
Thumbnail
DownloadPublished version (2.620Mb)
Publisher Policy

Publisher Policy

Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.

Terms of use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Metadata
Show full item record
Abstract
Copyright © 2018 by ASME. A method is presented to optimize the shape and size of a passive, energy-storing prosthetic foot using the lower leg trajectory error (LLTE) as the design objective. The LLTE is defined as the root-mean-square error between the lower leg trajectory calculated for a given prosthetic foot's deformed shape under typical ground reaction forces (GRFs), and a target physiological lower leg trajectory obtained from published gait data for able-bodied walking. Using the LLTE as a design objective creates a quantitative connection between the mechanical design of a prosthetic foot (stiffness and geometry) and its anticipated biomechanical performance. The authors' prior work has shown that feet with optimized, low LLTE values can accurately replicate physiological kinematics and kinetics. The size and shape of a single-part compliant prosthetic foot made out of nylon 6/6 were optimized for minimum LLTE using a wide Bezier curve to describe its geometry, with constraints to produce only shapes that could fit within a physiological foot's geometric envelope. Given its single part architecture, the foot could be cost effectively manufactured with injection molding, extrusion, or three-dimensional printing. Load testing of the foot showed that its maximum deflection was within 0.3 cm (9%) of finite element analysis (FEA) predictions, ensuring the constitutive behavior was accurately characterized. Prototypes were tested on six below-knee amputees in India-the target users for this technology-to obtain qualitative feedback, which was overall positive and confirmed the foot is ready for extended field trials.
Date issued
2018
URI
https://hdl.handle.net/1721.1/135867
Department
Massachusetts Institute of Technology. Global Engineering and Research Laboratory; Massachusetts Institute of Technology. Department of Mechanical Engineering
Journal
Journal of Mechanical Design
Publisher
ASME International

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.