MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Suppressing parametric instabilities in LIGO using low-noise acoustic mode dampers

Author(s)
Biscans, S; Gras, S; Blair, CD; Driggers, J; Evans, M; Fritschel, P; Hardwick, T; Mansell, G; ... Show more Show less
Thumbnail
DownloadPublished version (1.299Mb)
Publisher Policy

Publisher Policy

Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.

Terms of use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Metadata
Show full item record
Abstract
© 2019 American Physical Society. Interferometric gravitational-wave detectors like LIGO need to be able to measure changes in their arm lengths of order 10-18 m or smaller. This requires very high laser power in order to raise the signal above shot noise. One significant limitation to increased laser power is an optomechanical interaction between the laser field and the detector's test masses that can form an unstable feedback loop. Such parametric instabilities have long been studied as a limiting effect at high power, and were first observed to occur in LIGO in 2014. Since then, passive and active means have been used to avoid these instabilities, though at power levels well below the final design value. Here we report on the successful implementation of tuned, passive dampers to tame parametric instabilities in LIGO. These dampers are applied directly to all interferometer test masses to reduce the quality factors of their internal vibrational modes, while adding a negligible amount of noise to the gravitational-wave output. In accordance with our model, the measured mode quality factors have been reduced by at least a factor of 10 with no visible increase in the interferometer's thermal noise level. We project that these dampers should remove most of the parametric instabilities in LIGO when operating at full power, while limiting the concomitant increase in thermal noise to approximately 1%.
Date issued
2019
URI
https://hdl.handle.net/1721.1/136580
Department
LIGO (Observatory : Massachusetts Institute of Technology)
Journal
Physical Review D
Publisher
American Physical Society (APS)

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.